1.4
Specifications
1.4.1
General Description
Control Bus
Original bus (16-bit, 8 MHz, 10 megabytes per second)
Communication Bus
H.100 bus conformity (1024 time slots)
Switching
Non-blocking
Power Input
PSU-S
100 V AC to 130 V AC, 1.4 A/200 V AC to 240 V AC, 0.8 A, 
50 Hz/60 Hz
PSU-M
100 V AC to 130 V AC, 2.5 A/200 V AC to 240 V AC, 1.4 A, 
50 Hz/60 Hz
PSU-L
100 V AC to 130 V AC, 5.1 A/200 V AC to 240 V AC, 2.55 A, 
50 Hz/60 Hz
Maximum Power Failure Tolerance
*1
300 ms
Power Consumption
KX-TDA100 with PSU-S 140 W, 1.4 A (at 120 V AC, 60 Hz)
KX-TDA100 with PSU-M 210 W, 2.2 A (at 120 V AC, 60 Hz)
KX-TDA200 with PSU-M 240 W, 2.5 A (at 120 V AC, 60 Hz)
KX-TDA200 with PSU-L 490 W, 5.1 A (at 120 V AC, 60 Hz)
Memory Backup Duration
7 years
Dialing
CO Line
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialing
Extension
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialing
Mode Conversion
DP-DTMF, DTMF-DP
Ring Frequency
20 Hz/25 Hz (selectable)
Central Office Loop Limit
1600 
Ω maximum
Operating 
Environment
Temperature
0 °C to 40 °C (32 °F to 104 °F)
Humidity
10 % to 90 % (non-condensing)
Conference Call CO Line
From 10 × 3-party conference call to 4 × 8-party conference 
call
Music on Hold (MOH)
2 ports (Level Control: -11 dB to +11 dB in 1 dB steps)
MOH1: External Music Source port
MOH2: Selectable Internal/External Music Source port
Paging
Internal
Level Control: -15 dB to +6 dB in 3 dB steps
External
2 ports (Volume Control: -15 dB to +15 dB in 1 dB steps)
Serial Interface Port
RS-232C
1 (maximum 115.2 kbps)
USB