Toshiba ASD-G9ETH Manual Do Utilizador

Página de 106
 
  
103
ICC 
AI6 ........Similar to AI5, this object indicates the signal level currently being 
applied to the ASD's VI/II analog input terminal.  ASD parameter 
FE36. 
AI7 ........Similar to AI5, this object indicates the signal level currently being 
applied to the ASD's RX analog input terminal.  ASD parameter FE37. 
AI8 ........Indicates the present fault code.  Under normal operation (no faults), 
this value will be 0.  ASD parameter FC90. 
  
  
Analog Output Objects 
 
AO1 ......Sets the drive's frequency command in 0.01Hz units (e.g. 4000 = 
40.00Hz).  Note that the drive will only use this value as its active 
frequency command if the Frequency Mode parameter is set to 
“Communication Option Input Enabled ", or if the "frequency override" 
bit (BO6) is ON.  Although the adjustment range for this object is 0-
40000 (0.00Hz-400.00Hz), the actual frequency command will be 
internally limited by the Upper Limit Frequency and Lower Limit 
Frequency
 parameters.  ASD parameter FA07. 
AO2 ......Adjusts the FM analog output voltage if the “FM terminal meter 
selection” parameter is set to a value of 31 (communication data 
output).  Range is 0-2047 = 0-100%.  ASD parameter FA51. 
AO3 ......Adjusts the AM analog output voltage if the “AM terminal meter 
selection” parameter is set to a value of 31 (communication data 