ICC 
Input Instances 70 and 71 Detail 
 
Instance 
Byte 
Bit 
Bit 
Bit 
Bit 
Bit 
Bit 
Bit 
Bit 
 
 
 
 
 
Running
 Fault 
 
 
 
 
 
 
 
 
Speed Actual (Low Byte) 
70 
Speed Actual (High Byte) 
At 
Ref 
Ref 
From 
Net 
Ctrl 
From 
Net 
Rdy 
Running
2 (REV) 
Running
1 (FWD) 
Warn Fault 
1 Drive 
State 
Speed Actual (Low Byte) 
71 
Speed Actual (High Byte) 
 
 
Mapping Detail 
Faulted:  Inverter fault signal (0=not faulted, 1=faulted).  Maps to inverter 
register 1302 (status 1 word), bit 0. 
Warning:  This bit is not used (it is always 0). 
Running1 (FWD):  Running forward status signal (0=not running forward, 
1=running forward).  Maps to inverter register 1302 (status 1 word), bits 9 and 
10.  The Running1 bit will be 1 whenever inverter register 1302 bit 9 (direction) 
is 0 and bit 10 (running/stopped) is 1, and will be 0 otherwise. 
Running2 (REV):  Running reverse status signal (0=not running reverse, 
1=running reverse).  Maps to inverter register 1302 (status 1 word), bits 9 and 
10.  The Running2 bit will be 1 whenever inverter register 1302 bit 9 (direction) 
is 1 and bit 10 (running/stopped) is 1, and will be 0 otherwise. 
Ready:  Inverter ready signal (0=not ready, 1=ready).  The Ready bit will be 1 
whenever the Drive State attribute (see below) is in the Ready, Enabled or 
Stopping state. 
CtrlFromNet:  Inverter command reference status (0=command reference is not 
from network, 1=command reference is from network).  Maps to inverter 
register 1007, bit 15 (command priority).  In other words, CtrlFromNet always 
reflects the status of the NetCtrl attribute. 
RefFromNet:  Inverter speed reference status (0=speed reference is not from 
network, 1=speed reference is from network).  Maps to inverter register 1007, 
bit 14 (frequency priority).  In other words, RefFromNet always reflects the 
status of the NetRef attribute. 
AtReference:  Up-to-speed signal (0=not up-to-speed, 1=up-to-speed).  Maps 
to inverter register 1350 (status 3 word), bit 12 (RCH). 
Drive State:  Indicates the current state of the Control Supervisor Object state 
machine.  Refer to the ODVA Ethernet/IP specification (object library) for 