Yamaha 02R96 Manual Do Utilizador

Página de 315
128
Chapter 13—Libraries
02R96—Owner’s Manual
Comp Library
Comp settings can be stored in the Comp library, which contains 36 preset memories and 
92 user memories. See page 97 for information on the Comps.
1
Use the DYNAMICS [DISPLAY] button to select the Comp Library page.
2
Use the LAYER buttons to select Layers, and the [SEL] buttons to select chan-
nels.
When storing, the Comp settings of the currently selected channel, indicated in the 
upper-right corner, are stored to the selected memory. When recalling, the Comp settings 
in the selected memory are applied to the currently selected channel.
CURRENT TYPE: This indicates the current Comp type of the currently selected channel.
CURRENT CURVE: This is the Comp curve of the currently selected channel.
GR meters: These meters indicate the amount of gain reduction being applied by the 
Comp, and the levels of the currently selected channel and its adjacent channel. If Pair mode 
for the currently selected channel is set to Vertical, the level of its counterpart on the adja-
cent Layer is displayed.
The type (Comp, Expand, Comp Soft, Comp Hard) and curve of the currently selected 
memory is displayed to the right of the memory list.
For details on the Store, Recall, Title Edit, and Clear functions, see “General Library Oper-
ation” on page 122.