Yamaha 02R96 Manual Do Utilizador

Página de 315
Format Details
287
02R96—Owner’s Manual
change.
Meter data uses the unmodified DECAY value of the DSP. For the inter-
pretation of the value, refer to the PARAMETER CHANGE PARAMETER 
NUMBER LIST.
12.3.22 Parameter request (Remote Meter)
Reception
This is received if [Parameter change RX] is ON and the [Rx CH] matches 
the device number included in the SUB STATUS.
This is echoed if [Parameter change ECHO] is ON.
When this is received, the parameter specified by Address (refer to PA-
RAMETER CHANGE PARAMETER NUMBER LIST) will be transmitted 
on the [Rx CH] at 50 msec intervals for a duration of 10 seconds.
If Address UL= 0x7F is received, transmission of all meter data will be halt-
ed immediately. (disable)
Transmission
If [Parameter Change ECHO] is ON, this message is retransmitted without 
change.
12.3.23 Parameter change (Remote Time Counter)
When transmission is enabled by receiving a Request of Remote Time 
Counter, the Time Counter data is transmitted every 50 msec for 10 sec-
onds. When you want to transmit Counter information continuously, a 
Request must be transmitted within every 10 seconds.
Reception
This is echoed if [Parameter change ECHO] is ON.
Transmission
When transmission is enabled by receiving a Request, the Time Counter 
information is transmitted on [RxCH] channel every 50 msec for 10 sec-
onds.
Transmission will be disabled if the power is turned off and on again, or if 
the PORT setting is changed.
If [Parameter Change ECHO] is ON, this message is retransmitted without 
change.
12.3.24 Parameter request (Remote Time Counter)
Reception
This is received if [Parameter change RX] is ON and the [Rx CH] matches 
the device number included in the SUB STATUS.
This is echoed if [Parameter change ECHO] is ON.
When this is received, the Time Counter information is transmitted on the 
[Rx CH] channel every 50 msec for 10 seconds.
When the second byte of Address is received on 0x7F, data transmission 
will be halted immediately.
Transmission
If [Parameter Change ECHO] is ON, this message is retransmitted without 
change.
12.3.25 Parameter change (Automix Status)
When transmission is enabled by receiving a Request of Automix status, 
the Automix Status data is transmitted every second for 10 seconds. When 
you want to transmit the Automix Status information continuously, the 
Request must be transmitted continuously minimum within 10 seconds 
interval. The data is transmitted continuously while the transmission is en-
abled, even when the Automix Status on the 02R96 has been changed.
Reception
This is echoed if [Parameter change ECHO] is ON.
Transmission
When the transmission is set to enable by receiving a Request. The Auto-
mix Status data is transmitted on the [Rx CH] channel every second for 10 
seconds. The data is transmitted continuously while the transmission is 
enabled, even when the Automix Status on the 02R96 has been changed.
Transmission will be disabled if the power is turned off and on again, or if 
the PORT setting is changed.
If [Parameter Change ECHO] is ON, this message is retransmitted without 
change.
12.3.26 Parameter request (Automix Status)
Reception
This is received if [Parameter change RX] is ON and the [Rx CH] matches 
the device number included in the SUB STATUS.
This is echoed if [Parameter change ECHO] is ON.
When the data is received, the Automix Status data is transmitted on the 
[Rx CH] every second for 10 seconds.
When the second byte of Address is received on 0x7F, data transmission 
will be halted immediately (disable).
Transmission
If [Parameter Change ECHO] is ON, this message is retransmitted without 
change.
STATUS
11110000 F0
System exclusive message
ID No.
01000011 43
Manufacture's ID number (YAMAHA)
SUB STATUS
0001nnnn 1n
n=0-15 (Device number=MIDI Channel)
GROUP ID
00111110 3E
MODEL ID (digital mixer)
MODEL ID
00001011 0B
02R96
ADDRESS
00100001 21
Address UU
0aaaaaaa aa
Address UL
0aaaaaaa aa
Address LU
0aaaaaaa aa
Address LL 
DATA 0ddddddd dd
Data1 H
0ddddddd dd
Data1 L
    :
EOX
11110111 F7
End of exclusive
STATUS
11110000 F0
System exclusive message
ID No.
01000011 43
Manufacture's ID number (YAMAHA)
SUB STATUS
0011nnnn 3n
n=0-15 (Device number=MIDI Channel)
GROUP ID
00111110 3E
MODEL ID (digital mixer)
MODEL ID
00001011 0B
02R96
ADDRESS
00100001 21
Address UU
0aaaaaaa aa
Address UL
0aaaaaaa aa
Address LU
0aaaaaaa aa
Address LL 
DATA
0cccccccccc
Count H
0ccccccccCc
Count L
EOX
11110111 F7
End of exclusive
STATUS
11110000 F0
System exclusive message
ID No.
01000011 43
Manufacture's ID number (YAMAHA)
SUB STATUS
0001nnnn 1n
n=0-15 (Device number=MIDI Channel)
GROUP ID
00111110 3E
MODEL ID (digital mixer)
MODEL ID
00001011 0B
02R96
ADDRESS
00100001 22
Remote Time Counter
0000tttt 0t
0:Time Code, 1: Measure, Beat, Clock 
DATA 0ddddddd dd
Hour / Measure H
0ddddddd dd
Min / Measure L
0ddddddd dd
Sec / Beat
0ddddddd dd
Frame / Clock
EOX
11110111 F7
End of exclusive
STATUS
11110000 F0
System exclusive message
ID No.
01000011 43
Manufacture's ID number (YAMAHA)
SUB STATUS
0011nnnn 3n
n=0-15 (Device number=MIDI Channel)
GROUP ID
00111110 3E
MODEL ID (digital mixer)
MODEL ID
00001011 0B
02R96
ADDRESS
00100001 22
Remote Time Counter
0aaaaaaa aa
0:Transmission request, 
0x7F:Transmission stop request
EOX
11110111 F7
End of exclusive
STATUS
11110000 F0
System exclusive message
ID No.
01000011 43
Manufacture's ID number (YAMAHA)
SUB STATUS
0001nnnn 1n
n=0-15 (Device number=MIDI Channel)
GROUP ID
00111110 3E
MODEL ID (digital mixer)
MODEL ID
00001011 0B
02R96
ADDRESS
00100011 23
Automix Status
00000000 00
DATA 0000dddd 0d
Automix Status H
0000dddd 0d
Automix Status L
EOX
11110111 F7
End of exclusive
STATUS
11110000 F0
System exclusive message
ID No.
01000011 43
Manufacture's ID number (YAMAHA)
SUB STATUS
0011nnnn 3n
n=0-15 (Device number=MIDI Channel)
GROUP ID
00111110 3E
MODEL ID (digital mixer)
MODEL ID
00001011 0B
02R96
ADDRESS
00100011 23
Automix Status
0aaaaaaa aa
0:Transmission request, 
0x7F:Transmission stop request
EOX
11110111 F7
End of exclusive