Yamaha 02R96 Manual Do Utilizador

Página de 315
Slot I/O
47
02R96—Owner’s Manual
Setting the Transfer Format for Higher Sampling Rates
The data transfer format for the higher sampling rates can be set as follows.
1
Use the DISPLAY ACCESS [DIO] button to locate the Higher Sample Rate Data 
Transfer Format page.
2
Use the cursor buttons to select the parameters, and use the Parameter 
wheel, INC/DEC buttons, or [ENTER] button to set them.
The SLOT TYPE column displays the names of any installed I/O Cards.
IN/OUT: These parameters are used to set the input and output data transfer format of I/O 
Cards when running at the higher sampling rates (i.e., 88.2 kHz or 96 kHz) to either Double 
Channel or Double Speed. In Double Speed mode, digital audio data is received and trans-
mitted at the current higher sampling rate (i.e., 88.2 kHz or 96 kHz). In Double Channel 
mode, digital audio data is received and transmitted at a sampling rate that is exactly half 
the current higher sampling rate and data is handled by two channels, thereby reducing the 
total number of inputs or outputs for an eight channel I/O Card to four. In Double Channel 
mode, the even-numbered channels are disabled. Double Channel mode allows you to 
record 96 kHz audio to legacy 44.1/48 kHz digital multitrack recorders.
The IN and OUT parameters are only available when a higher sampling rate (i.e., 88.2 kHz 
or 96 kHz) is selected. When the sampling rate is 44.1 kHz or 48 kHz, all parameters on this 
page are unavailable. As are individual parameters for Slots with analog I/O Cards installed, 
or no I/O Card installed. When a digital I/O card that does not support 88.2/96 kHz is 
installed, such as the MY8-AE, MY8-AT, or MY8-TD, its IN and OUT formats are fixed at 
Double Channel mode.
SRC: These parameters are used to turn on and off the sampling rate converter for each 
pair of Slot Inputs. When on, the sampling rate of the received digital audio is converted to 
the 02R96’s current sampling rate. The original sampling rate is displayed. These parame-
ters are available only when an I/O Card with onboard sampling rate converters is installed, 
such as the MY8-AE96S.