Yamaha AX44 Manual Do Utilizador

Página de 51
 
Troubleshooting
 
5
 
AX44—Owner’s Manual
 
Troubleshooting
 
Trouble
Advice
 
Lost the AX44 fixing screws?
Replace with M3 x 6 mm machine screws. 
Do not use screws longer than 6 mm as they 
may damage the AX44.
The AX44 does not work and the Power 
indicator is off?
Make sure that the computer is turned on.
Make sure the power connector is properly 
connected to the AX44.
Make sure the supplied 20-pin cable is con-
nected properly between the AX44 and 
DS2416.
The Power indicator is on but the AX44 still 
doesn’t work?
A single AX44 should be connected to 
DS2416 connector “IO-A”; the second AX44 
to connector “IO-B”.
The input signal sounds distorted?
Reduce the level of the input signal.
When connecting line-level equipment to 
inputs 1 and 2, set the Mic/Line switches to 
Line.
The input signal is too quiet?
Low-level signal sources such as micro-
phones should be connected to inputs 1 and 
2 and the Mic/Line switch set to Mic.
Cannot hear anything in the headphones?
The headphone signal is derived from out-
puts 3 and 4, so you must assign signals to 
these outputs in order to use the head-
phones.