Sanyo VCC-ZM400 Manual Do Utilizador

Página de 68
OPTION SETTING
B
Color/black & white selection setting (DAY/NIGHT)
The ALARM IN terminal on the rear panel can be used to force
the image mode to color mode or black & white mode. Use this
setting when using this terminal to force the mode selection.
However, when this setting is being used, external alarm input
cannot be received.
1
Set DAY/NIGHT in the LENS setting screen to “COLOR”.
First change the DAY/NIGHT setting in the LENS setting screen
to “
COLOR”. (See p23)
2
Color/black & white selection setting
Use the cursor button (j or l) to move the cursor to
ALM for ALARM IN, and then use the cursor button (
d
or c) to set the input (e.g. COLOR).
ALM: The control terminal (ALARM IN) is used for alarm input.
COLOR: The control terminal (ALARM IN) is used for
color/black & white selection input. External operations can
then be used to forcibly switch the mode to color mode or
black & white mode.
3
POLARITY setting
Use the cursor button (j or l) to move the cursor to
POLARITY, then use the cursor button (
d or c) to select
“NO” or “NC”.
Available settings:
NO: Normally open (Normally open, and mode switches
between color and black & white when closed)
NC: Normally closed (Normally closed, and mode switches
between color and black & white when opened)
POLARITY setting
Between ALARM
IN - COM terminals
Mode after
selection
When set to NO
Open
COLOR
Closed
B/W
When set to NC
Open
COLOR
Closed
B/W
Note:
If DAY/NIGHT has been set to “
COLOR”, color/black &
white selection will not be possible.
If COLOR is selected, settings relating to external alarm
input will not be displayed, and it will not be possible to
receive external alarm inputs.
The color/black & white selection setting is applied from the
point after the menu is exited.
1
          LENS
 FOCUS           MANU ‚
 ZOOM            SET  ‚
 DAY/NIGHT       COLOR‚
 VIEW ANGLE      OFF
 PRESET          OFF
 MENU            BACK
2, 3
    ALARM SETTING
 ALARM IN        ALM
  POLARITY       NO
  MOTION         OFF
  DURATION       5S
 ALARM OUT       OFF
  POLARITY       NO
  ALARM TIME     5S
 LINE OUT        OFF
 PRESET          OFF
 MENU            BACK
L5AD2/US (VCC-ZM400)  GB  2003, 2, 4
En
g
lis
h
59