Trimble Outdoors r7 Manual Do Utilizador

Página de 222
Trimble R7/R8 GPS Receiver User Guide     1 3 7
Configuration     1 5
Tr
imble R8 Operation
When you switch off the receiver then turn it on again, all the settings 
from the current application file are applied, so you do not lose any 
changes that you have made. The only exceptions are the following 
logging parameters:
Logging rate
Position rate
Elevation mask
These parameters are always reset to the factory default values 
whenever the receiver is switched off.
Power Up application file
The power up application file (Power_up.cfg) is used to set the 
receiver to a specific configuration any time the unit is powered up. 
You can specify that the receiver is reset to defaults before the power 
up settings are applied. This ensures that restarting the receiver always 
resets it to factory defaults prior to applying the power up application 
file.
Alternatively, you can specify that the power up settings are applied 
immediately after the current application file’s settings have been 
applied. Restarting the receiver results in a configuration that uses 
your default settings for the options you define in the power up file, 
but the current settings for all other options.
By default, there is no POWER_UP application file on the receiver. To 
use a power up application file, you must create and save a 
POWER_UP application file in GPS Configurator. If you save this file 
to disk, the file is called Power_up.cfg. The extension .cfg is used by 
convention to identify application files on the office computer.   When 
you transfer this file to the receiver, the file is saved on the receiver as 
POWER_UP, and becomes the new power up file.
The power up file is the only special application file that you can 
overwrite or delete from the receiver.