Cheetah 15K.4 FC Product Manual, Rev. B
21
The thermal monitor system generates a warning code of 01-0B01 when the temperature exceeds the speci-
fied limit in compliance with the SCSI standard. The drive temperature is reported in the FRU code field of 
mode sense data. You can use this information to determine if the warning is due to the temperature exceeding 
the drive threatening temperature or the user-specified temperature.
This feature is controlled by the Enable Warning (EWasc) bit, and the reporting mechanism is controlled by the 
Method of Reporting Informational Exceptions field (MRIE) on the Informational Exceptions Control (IEC) 
mode page (1Ch).
The current algorithm implements two temperature trip points. The first trip point is set at 65°C which is the 
maximum temperature limit according to the drive specification. The second trip point is user-selectable using 
the Log Select command. The reference temperature parameter in the temperature log page (see Table 1) ca
be used to set this trip point. The default value for this drive is 65°C, however, you can set it to any value in the 
range of 0 to 65°C. If you specify a temperature greater than 65°C in this field, the temperature is rounded 
down to 65°C. A sense code is sent to the host to indicate the rounding of the parameter field.
5.2.6
Drive Self Test (DST)
Drive Self Test (DST) is a technology designed to recognize drive fault conditions that qualify the drive as a 
failed unit. DST validates the functionality of the drive at a system level. 
There are two test coverage options implemented in DST:
1. Extended test
2. Short text
The most thorough option is the extended test that performs various tests on the drive and scans every logical 
block address (LBA) of the drive. The short test is time-restricted and limited in length—it does not scan the 
entire media surface, but does some fundamental tests and scans portions of the media. 
If DST encounters an error during either of these tests, it reports a fault condition. If the drive fails the test, 
remove it from service and return it to Seagate for service.
5.2.6.1
DST failure definition
The drive will present a “diagnostic failed” condition through the self-tests results value of the diagnostic log 
page if a functional failure is encountered during DST. The channel and servo parameters are not modified to 
test the drive more stringently, and the number of retries are not reduced. All retries and recovery processes 
are enabled during the test. If data is recoverable, no failure condition will be reported regardless of the number 
of retries required to recover the data.
The following conditions are considered DST failure conditions:
• Seek error after retries are exhausted
• Track-follow error after retries are exhausted
• Read error after retries are exhausted
• Write error after retries are exhausted
Recovered errors will not be reported as diagnostic failures.
Table 1:
Temperature Log Page (0Dh)
Parameter Code
Description
0000h
Primary Temperature
0001h
Reference Temperature