Siemens optipoint 410 s v6.0 Manual Do Utilizador

Página de 154
xml_03.fm
A31003-J4260-M101-2-76A9, 03-2007
XML Configuration Management, Administrator Manual
3-13
    
   
   
XML Overview
Administration Tags
3.3.3.12
SIP Port
3.3.3.13
RTP Base Port
3.3.3.14
Outbound proxy
3.3.3.15
Default ODP domain name
Parameter
sip-port
WEB 
Index
Value
0 to 65535
Integer; default 5060
Example
<Item name="sip-port">5060</Item> 
Notes
reg-addr, registrar-addr, sgnl-route, if port=0 e164
Parameter
rtp-base-port
WEB 
Index
Value
0 to 65535
Integer; default: 5004
Example
<Item name="rtp-base-port">5004</Item> 
Notes
e164
Parameter
outbound-proxy
WEB 
Index
Value
true, false
Boolean, on or off
Example
<Item name="outbound-proxy">true</Item> 
Notes
e164
Parameter
default-domain
WEB 
Index
Value
Aabcdefg1234
Default outbound proxy domain (al-
phanumeric)
Example
<Item name="default-domain">as.broadworks.net</Item> 
Notes
e164