2-17
Software Setup
Defining System Defaults
Use the Define Defaults Menu to change the default values that 
are stored in memory and used when the switcher is turned on. 
(You may also use the 
CLEAR WORK BUFR 
button)
The values 
stored in the User-Defined Default Buffer (battery-backed RAM) 
are loaded into the Working Buffer when power is applied to the 
switcher. This sets the initial state of the switcher parameters.
1.
With the
 M/E SELECT
 button, select the M/E whose settings you 
want to be used during power-up. (Only one set of values is 
stored for the M/Es, therefore both M/Es will use the same 
values at boot-up.)
2.
On the switcher panel (including the selected M/E), set up the 
switcher state that you want the switcher to assume when it is 
turned on.
3.
Press
 SET DEFAULT
 to enter the new default values.
4.
Pressing the
 GVG DEFAULT
 button will restore the factory-set 
default values to the switcher. These are stored in non-volatile 
memory (ROM).
DEFINE DEFAULTS MENU
ME1
config / user prefs / define defaults
M/E
SELECT
SET
DEFAULT
ME2
GVG
DEFAULT
Set Default State to Current Switcher State. All M/Es will use  ME1  settings
Set Default State to GVG Factory Default.