Tektronix 2200 Manual Do Utilizador

Página de 272
2-41
Software Setup
Configuring GPI Outputs
Use the GPI Outputs Menu to set E-MEM levels for each assigned 
GPI. You can also set up GPI outputs which trigger each time there 
is a cut on the PGM Bus, and set the length of the GPI trigger 
signal. This menu is accessed from the Config/External If Menu.
1.
Use the 
PGM CUT TRIGGER
 button to select a GPI number which 
will trigger each time there is a cut on the PGM Bus. This GPI 
is typically connected to an external device such as a clock/
timer which is reset by each trigger. Such a clock would then 
indicate how long the current source has been on air.
2.
Use the 
SELECT GPI 
button to select the desired GPI number.
3.
Press the 
E-MEM LEVEL 
button to select the desired E-MEM level 
for the selected GPI number.
4.
Use the 
LENGTH 
soft knob to select (in number of fields) the 
required GPI duration. Use this to set the duration of GPI 
output triggers.
5.
Repeat Steps 1 through 3 for other GPIs.
GPI OUTPUTS MENU
GPI 7
GPI 6
GPI 5
GPI 4
GPI 3
GPI 2
GPI 1
OFF
config / external if / gpi outputs
PGM CUT
TRIGGER
E-MEM
LEVEL
LENGTH
=  1 Field
GPI 8
7
SELECT
GPI
DPM 3
DPM 2
DPM 1
MISC
DPM 4
5
6
8
7
MISC
MISC
MISC
MISC
4
MISC
3
MISC
2
MISC
1
MISC
LEVEL
LENGTH
1
1
1
1
1
1
1
1