Tektronix 2200 Manual Do Utilizador

Página de 272
2-48
Section 2— Startup and Configuration
Peripheral Bus II (Port A3 Only)
 
— PBusII is used for run control of 
effects using triggers. With current software, PBusII triggers are 
learned into the
 MISC 
E-MEM level. For example, when using 
PBusII as the control connection for a DPM-700, the following 
should be set in the DPM Setup Menu:
PORT ASSIGN
 = 
NONE
CHANNEL ROUTING
 = OFF
GPIs
—Both input and output GPIs may be used as triggers as part 
of the control interface between the DPM and switcher. 
Depending on the nature of the DPM, GPIs can be used for effect 
recall and run control, source selection, and tally information.
Configuring the DPM Interface
Set up the DPM type, port assignment, channel routing, video 
delay, and control delay as follows:
From the External Interface Menu, press 
DPM IF>
 to bring up the 
DPM Setup Menu.
DPM SETUP MENU
CONTROL DELAY
= 6 fields
DPM
TYPE
DEVICE
SELECT
DPM MAP
 AUX BUSES >
DPM 1
DPM MAP
 INPUTS >
KRYSTAL
NONE
NONE
NONE
NONE
NONE
-
-
-
DPM 2
DPM 3
DPM 4
VIDEO DELAY
= 2 fields
config / extern if / dpm setup
6
0
0
2
0
0
CTRL DELAY
VIDEO DELAY
DPM 1
BOTH
PORT A1
6
2
PORT
ASSIGN
CHANNEL
ROUTING
K'SCOPE
SOURCES>
PORT A2
NONE
SWR IN
SWR OUT
OFF
BOTH
PORT A1
OTHER FIXED
NONE
KRYSTAL
KSCOPE
KSCOPE