Alto-Shaam platinum series asc-4g Manual Do Utilizador

Página de 30
ASC-4G  Gas  Convection  Oven  -  Electronic  Control  •  4
I n S t A l l A t I o n
I n S t A l l A t I o n
MINIMUM 6 INCH 
CLEARANCES FROM
COMBUSTIBLES AND 
NON-COMBUSTIBLES
Ne pas installer à
une distance inférirure
à celle indiquée 
ci-dessous d'une paroi 
en matiére combustible: 
Côtés 6 pouches, 
Arriére 6 pouches
FOR USE ONLY ON
NON-COMBUSTIBLE 
FLOORS.
Doit être utilisé 
seulement sur des 
planchers non 
inflammables.
INTENDED FOR
OTHER THAN
HOUSEHOLD USE.
Destiné à un usage
autre que domestique.
3107173
The oven must be mounted on the factory equipped 
oven legs or on an optional oven stand.  Installation 
on a solid or concrete base that in any way restricts 
air flow may void the warranty.
All clearances for a proper ventilation air supply 
must be maintained to minimize fire hazard.  Do 
not locate the oven immediately adjacent to any 
other heat-generating appliance.
A number of adjustments are associated with 
initial installation and start-up.  Adjustments 
must be conducted by a qualified service 
technician.  Installation and start-up adjustments 
are the responsibility of the dealer or user.  
These adjustments include but are not limited to 
thermostat calibration, door adjustment, leveling,  
and gas pressure verification.  The Platinum series 
oven burners are factory-adjusted with fixed air 
openings and require no field adjustment.
lEvElInG
The oven should be 
leveled before the gas 
supply is connected.  Level the oven from 
side-to-side and front-to-back with the use of a 
spirit level.  For ovens installed on a mobile stand, 
it is important that the floor surface be level due to 
the probability of frequent oven repositioning.
We recommend checking the level of the oven 
periodically to make certain the floor has not 
shifted or the oven moved.
notE: 
  Failure to properly level this oven can 
cause improper function as a result 
of erratic burner combustion and will 
result in the uneven baking of products 
consisting of semi-liquid batter.
I n S t A l l A t I o n   R E Q u I R E M E n t S 
w A R n I n G
Inadequate ventilation, or failure to 
ensure an adequate supply of fresh 
air will result in a high ambient 
temperature at the rear of the 
appliance.  An excessive ambient 
temperature can cause the thermal- 
overload protection device on the 
blower motor to trip resulting in 
severe damage to the blower motor.
C A u t I o n
TO PREVENT PERSONAL INJURY, 
USE CAUTION WHEN MOVING OR 
LEVELING THIS APPLIANCE.
30-5/8" (778mm)
44-1/2" (1
130mm)
58-1/2" (1486mm)
31-15/16" (810mm)
38" (965mm)
25-11/16" (652mm)
3-5/16" (84,4mm)
29-1/8" (740mm)
1/2" 
GAS INLET
3-5/32"
(80,1mm)
6-15/16" (176mm)
9-15/16" (252mm)
LINE CORD ENTRANCE
31-1/16" (789mm)
4" (102mm)
1/2" GAS INLET
EXHAUST
VENT
CAVITY WIDTH
123°
129°
26-1/2" (673mm)
54-5/8" (1387mm)
3-11/16" (93mm)
6' (1828mm) 
LINE CORD ENTRANCE
12-15/16" (329mm)
MoDEl ASC-4G
Electronic Control
pRoDuCt\pAn CApACIty
72 lb (33 kg) 
MAXIMUM
45 qts (43 liters)
 12 (twelve): 
18" x 26" x 1" 
FULL
-
SIZE
 
SHEET
 
PANS