ASC-2E  &  ASC-4E  Electric  Convection  Ovens  -  Electronic  Control  •  5
I n S t A l l A t I o n
The oven must be mounted on the factory equipped 
oven legs or on an optional oven stand.  Installation 
on a solid or concrete base that in any way restricts 
air flow may void the warranty.
All clearances for a proper ventilation air supply 
must be maintained to minimize fire hazard.  Do not 
locate the oven immediately adjacent to any other 
heat-generating appliance.
A number of adjustments are associated with 
initial installation and start-up.  Adjustments 
must be conducted by a qualified service 
technician.  Installation and start-up adjustments 
are the responsibility of the dealer or user.  
These adjustments include but are not limited 
to thermostat calibration, door adjustment, and 
leveling.  The Platinum series oven burners are 
factory-adjusted with fixed air openings and require 
no field adjustment.
lEvElInG
The oven should be leveled before 
the gas supply is connected.  level the oven from 
side-to-side and front-to-back with the use of a 
spirit level.  For ovens installed on a mobile stand, 
it is important that the floor surface be level due to 
the probability of frequent oven repositioning.
We recommend checking the level of the oven 
periodically to make certain the floor has not 
shifted nor the oven moved.
I N S T a l l a T I O N   R E Q u I R E M E N T S 
d A n G E R
IMPROPER INSTALLATION, 
ALTERATION, ADJUSTMENT, 
SERVICE, OR MAINTENANCE COULD 
RESULT IN SEVERE INJURY, DEATH, 
OR CAUSE PROPERTY DAMAGE.
READ THE INSTALLATION, 
OPERATING AND MAINTENANCE 
INSTRUCTIONS THOROUGHLY 
BEFORE INSTALLING OR SERVICING 
THIS EQUIPMENT.
C A U t I o n
TO PREVENT PERSONAL INJURY, 
USE CAUTION WHEN MOVING OR 
LEVELING THIS APPLIANCE.
RESTRAINT REQUIREMENTS 
—MOBILE EQUIPMENT
Any appliance that is not furnished with a power 
supply cord but includes a set of casters must be 
provided with a tether.  Adequate means must be 
provided to limit the movement of this appliance 
without depending on or transmitting stress to the 
electrical conduit.  The following requirements apply:
1.
    Casters must be a maximum height of 6" (152mm).
2.    
Two of the casters must of be the locking type.
3.    
Such mobile appliances or appliances on mobile 
stands must be installed with the use of a flexible 
connector secured to the building structure.
A mounting connector for a restraining device 
is located on the lower back flange of the appliance 
chassis or on an oven stand, approximately 
18" (457mm) from the floor.  A flexible connector 
is not supplied or available from the factory.
    w A R n I n G
RISk Of ElEcTRIc ShOck.
Appliance must be secured 
to building structure.
Where automatically operated appliances are vented through a ventilating hood or 
exhaust system equipped with a damper or with a power means of exhaust, provisions 
shall be made to allow the equipment to operate only when the damper is open to a 
position to properly vent the appliance and when the power means of exhaust is in 
operation.   
A C C O R D A N C E
 
W I T H
 NFPA 54 
C O M M O N W E A L T H
 
O F
 
M A S S A C H U S E T T S
 
O N L Y
.