Trimble Outdoors 58052-00 Manual Do Utilizador
2 PRODUCT DESCRIPTION
3 8 Copernicus GPS Receiver
Normal Operating Conditions
Minimum and maximum limits apply over full operating temperature range unless
otherwise noted.
otherwise noted.
* The rise time to VCC MUST be greater than 140 μsecs. The user can use one source of power on Pin 12 (VCC) for both
main and Standby power.
main and Standby power.
** If using two sources of power, the Main and Standby power must be connected to VCC via an external diode-pair.
During the Standby Mode, the main power can be removed so the unit can be run on Standby power. Standby power
must be at least 0.3V less than main power. The voltage at Pin 12 must be 2.7V to 3.3V including the diode voltage drop.
(See Chapter 5 for information on application circuits.)
During the Standby Mode, the main power can be removed so the unit can be run on Standby power. Standby power
must be at least 0.3V less than main power. The voltage at Pin 12 must be 2.7V to 3.3V including the diode voltage drop.
(See Chapter 5 for information on application circuits.)
Parameter
Conditions
Min
Typ
Max
Unit
Primary Supply Voltage *
The rise time to VCC MUST
be greater than 140 μsecs
be greater than 140 μsecs
2.7
3.3 *
V
Current Draw
Continuous Tracking,
Continuous Tracking,
Max: 85°
C
, 3.3 V
Min: -40° C, 2.7V
Typ: 25° C, 3.0 V
23.9
34.8
38.3 mA
Power Consumption
Continuous Tracking,
Max: 85° C, 3.3 V
Min: -40° C, 2.7V
Typ: 25° C, 3.0 V
79
93.9
115 mW
Power Consumption
Absolute Maximum
50
165
mA
mW
Current Draw **
Standby Mode
Max: 85° C,
Min: -40° C
Typ: 25° C, 3.0 V
7.1
8.5
60 uA
Current Draw Standby
Mode RTC Service
Mode RTC Service
30
Please see section
Serial Port Activity
Serial Port Activity
mA
Supply Ripple Noise
1Hz to 1MHz
GPS TCXO
Frequency
Frequency
±
5kHz
50
1
mVpp
mVpp
Hardware RESET
Assert XRESET pin to clear
STANDBY memory
STANDBY memory
100
us