Page 28
Overload Heaters for Overload Relays Table
OVERLOAD  HEATER  TABLE
Motor Full Load Amps (FLA)
Heater
Size
H-6
H-7
H-8
H-9
H-10
H-11
H-12
H-13
H-14
H-15
H-16
H-17
H-18
H-19
H-20
H-21
H-22
H-23
H-24
H-25
H-26
H-27
H-28
H-29
H-30
H-31
H-32
H-33
H-34
SF = 1.00
40 Deg. C
Amb.
.69 - .74
.75 - .83
.84 - .93
.94 - 1.02
1.03 - 1.16
1.17 - 1.31
1.32 - 1.45
1.46 - 1.63
1.64 - 1.80
1.81 - 1.96
1.97 - 2.22
2.23 - 2.43
2.44 - 2.55
2.56 - 2.81
2.82 - 2.99
3.00 - 3.43
3.44 - 3.90
3.91 - 4.28
4.29 - 4.86
4.87 - 5.45
5.46 - 6.13
6.14 - 6.79
6.80 - 7.72
7.73 - 8.48
8.49 - 9.65
9.66 - 10.70
10.80 - 12.30
12.40 - 13.00
13.10 - 14.00
60 Deg. C
Amb. or more
.56 - .61
.62 - .68
.69 - .74
.75 - .83
.84 - .93
.94 - 1.02
1.03 - 1.16
1.17 - 1.31
1.32 - 1.45
1.46 - 1.63
1.64 - 1.80
1.81 - 1.96
1.97 - 2.22
2.23 - 2.43
2.44 - 2.55
2.56 - 2.81
2.82 - 2.99
3.00 - 3.43
3.44 - 3.90
3.91 - 4.28
4.29 - 4.86
4.87 - 5.45
5.46 - 6.13
6.14 - 6.79
6.80 - 7.72
7.73 - 8.48
8.49 - 9.65
9.66 - 10.70
10.80 - 12.30
SF = 1.15 OR GREATER
60 Deg. C
Amb. or more
.51 - .55
.56 - .61
.62 - .68
.69 - .74
.75 - .83
.84 - .93
.94 - 1.02
1.03 - 1.16
1.17 - 1.31
1.32 - 1.45
1.46 - 1.63
1.64 - 1.80
1.81 - 1.96
1.97 - 2.22
2.23 - 2.43
2.44 - 2.55
2.56 - 2.81
2.82 - 2.99
3.00 - 3.43
3.44 - 3.90
3.91 - 4.28
4.29 - 4.86
4.87 - 5.45
5.46 - 6.13
6.14 - 6.79
6.80 - 7.72
7.73 - 8.48
8.49 - 9.65
9.66 - 10.70
40 Deg. C
Amb.
.62 - .68
.69 - .74
.75 - .83
.84 - .93
.94 - 1.02
1.03 - 1.16
1.17 - 1.31
1.32 - 1.45
1.46 - 1.63
1.64 - 1.80
1.81 - 1.96
1.97 - 2.22
2.23 - 2.43
2.44 - 2.55
2.56 - 2.81
2.82 - 2.99
3.00 - 3.43
3.44 - 3.90
3.91 - 4.28
4.29 - 4.86
4.87 - 5.45
5.46 - 6.13
6.14 - 6.79
6.80 - 7.72
7.73 - 8.48
8.49 - 9.65
9.66 - 10.70
10.80 - 12.30
12.40 - 13.00