Human Interface Module (HIM) Operation
When power is first applied to the drive, the HIM will 
cycle through a series of displays. The displays will 
show drive name, HIM ID number, and 
communications status. Upon completion, the Status 
Display will be displayed. If a fault condition exists, it 
will appear on the display.
NOTE: If “Not Enabled” is displayed, the Enable 
input is not active. Check that the door is closed 
and locked, or that all necessary jumpers are in 
place. Refer to Section 2 of this manual.
Figure 55 
HIM – Key Explanation
Escape key. Use to return to last or original 
position.
Select key. Use to move cursor position.
Up arrow key. Scroll up.
Down arrow key. Scroll down.
Enter key. Use to enter program selection or new 
parameter value.
The structure charts on the following pages illustrate 
how to navigate between the levels to obtain 
information necessary for troubleshooting for earlier 
and later HIM versions.
The HIM Structure is broken into 4 levels: Operator 
Level, Mode Level, Group Level (Main File for earlier 
versions), and Parameter Level.
In the Group Level (Main File for earlier versions), 
only three Groups are used: Metering, Faults, and 
Linear List. Most diagnostic information is found in 
Metering or Faults.
ESC
SEL
Stopped
+0.00 Hz
U093M
Human Interface Module (HIM)
ESC
SEL