PowerFlex 40 and 400 Drive Control Logic
F232120
26
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Table 16 (continued)
 PowerFlex 40
Parameter 
Group and 
Number
PowerFlex 400 Parameter Group 
and Number
Parameter 
Description
Function
d029
b013
Torque Current
Displays the present value of the motor's 
torque current (in Amps).
d030
N/A
OL Level
Displays the real-time motor overload 
progression (100% = F007 Fault).
P041
P041
Reset to Defaults
NOTE: This will reset the drive's 
parameters back to the factory-default 
values, requiring the AC drive to be re-
programmed. This will not reset A193. 
(0 = Not Active; 1 = Reset - Induces 
Fault F048).
A101
A198
Parameter Lock
Allows parameter modification.
0 = Parameters Unlocked
1= Parameters Locked
See also parameters A192 and A193.
A152
N/A
Limited 
Frequency
Displays the maximum allowable 
frequency (in Hz) based on DC Bus 
voltage. The drive output frequency may 
be limited due to low input voltage 
conditions to alleviate potential motor 
stalling.
A164
R261
Balance State
Displays the balance detection algorithm 
progression (See A187 and A188). (0 = 
Algorithm not active; 1 = programmed 
pause time; 2 = programmed sample 
time; 3 = programmed filter time; 4 = 
result obtained)
A187
N/A
SmartSpin 
Frequency
Displays the commanded SmartSpin 
frequency (in Hz) as determined from 
Balance Result A188.
A188
R285
Balance Result
Displays the numeric value indicating 
severity of load imbalance. A balance 
result value will be displayed only when 
A164 = 4, otherwise the display will be 
0.
A192
N/A
Parameter 
CRC-16
Displays the numeric code culminating 
from the value of all of the parameters. 
This is intended as a quick reference and 
is used to validate the parameter settings 
for a specific application.
Table 16 (continued)