Alliance Laundry Systems 1305 Manual Do Utilizador
PowerFlex 40 and 400 Drive Control Logic
F232120
30
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Figure 19
PHM640
Number
Name
Description
1
Escape
Back one step in programming menu.
Cancel a change to a parameter value and exit Program Mode.
Cancel a change to a parameter value and exit Program Mode.
2
Select
Advance one step in programming menu.
Select a digit when viewing parameter value.
Select a digit when viewing parameter value.
3
Up Arrow
Down Arrow
Down Arrow
Scroll through groups and parameters.
Increase/decrease the value of a flashing digit.
Increase/decrease the value of a flashing digit.
4
Enter
Advance one step in programming menu.
Save a change to a parameter value.
Save a change to a parameter value.
5
Stop
Used to stop the drive or clear a fault. This key is always active.
Controlled by parameter P037 (Stop Mode).
Controlled by parameter P037 (Stop Mode).
6
Reverse
Used to reverse direction of the drive. Default is active.
Controlled by parameters P036 (Start Source) and A095 (Reverse Disable).
Controlled by parameters P036 (Start Source) and A095 (Reverse Disable).
7
Start
Used to start the drive. Default is active.
Controlled by parameters P036 (Start Source).
Controlled by parameters P036 (Start Source).
8
Potentiometer
Used to control speed of drive. Default is active.
Controlled by parameter P038 (Speed Reference).
Controlled by parameter P038 (Speed Reference).
RUN
FWD
REV
VOLTS
PROGRAM
AMPS
HERTZ
FAULT
POWERFLEX KEYPAD BUTTONS
2
5
8
6
4
1
3
7