9.3  PLU ENTRY USING RS-232 INTERFACE 
 
This method enables the user to send the data from a PC program as well as 
from  the  keypad.  The  most  common  PLUs  can  be  stored  and  recalled  from 
the  scale  memory.  Other  PLU  data  can  be  stored  on  a  PC,  then  the 
Description  (text  data),  Unit  Weight  and  Tare  Weight  data  can be sent from 
the PC for the PLUxx (where xx can be any desired number up to 99). This 
can then be used or over-written during operation. 
 
OPERATION: 
 
  Send Tare Weight data to set any tare value to be stored with PLU.   
i.e. “
T 1.45
” <CR>. If no tare is needed then you may send “
T 0
” to delete 
any present tare data. 
 
  Send the Unit Weight to be stored with PLU. i.e. “
U0.015
” <CR> 
 
  Send PLU text data to be stored with current Tare and U/W values. 
i.e. “
SPLU27, M4 Nut Brass
” <CR> 
 
Any  information  stored  for  the  Tare  Weight,  Description  and  the  Unit weight 
will be stored in the scale and can be recalled for use in the future.