Adtran 4175043L2 Manual Do Utilizador

Página de 192
Chapter 3. Configuration
3-24
MX2800 STS-1 User Manual
61200659L1-1
Power Supply Alarms
Alarm
Description
Activity Loss 
Status
When enabled, the CRITICAL relay will be 
thrown if the Activity Loss Status indicates the 
failure of an internal clock. The alarm will remain 
active until the condition clears or the alarm is 
acknowledged by the user. 
Alarm
Description
Malfunction
Power supply card is no longer working. The 
unit has switched to the backup power supply or 
battery backup.
Power Low
Power supply’s output level is abnormally low.
Power Fail
Power supply card’s input power is lost.
Bat. Backup 
Active
Battery charger has lost its AC source and is 
now running off the battery backup.
Battery Low
Battery backup has reached a critical energy 
point at which it may be unable to supply the unit 
with sufficient power to maintain operation.
Temperature 
High
Power supply card temperature is above 
normal.
Temperature 
Critical
Power supply card temperature is so high that it 
may suffer damage.