Alliance Laundry Systems 70400401r2 Manual Do Utilizador

Página de 24
Operation
13
70400401
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
DMP OPL Features
DIP Switch Settings
The DMP has an 8 position DIP switch bank that is 
accessible from the back of the control board. By 
switching these DIP switches, it is possible for the 
operator to customize the display and some of the 
operating features of the tumbler. 
DIP Switch Functions Explained
1. Tumbler Type: This DIP switch selects the type 
of tumbler, i.e., OPL or Coin.
2. Temperature Units: Selects ºF or ºC for the 
temperature display. Factory setting is for ºF.
3. Local/Remote Reversing: Preset at the factory; 
usually for local reversing. Remote reversing for 
use with Reversing Timer Board only. 
4. Empty: Preset at the factory; always ON.
5. Empty: Preset at the factory; always ON.
6. Buzzer Timer: This DIP switch determines the 
length of time that the end of cycle buzzer will 
remain on. “OFF” indicates that the buzzer will 
sound for 5 seconds when the drying cycle is 
completed. “ON” indicates that the buzzer will 
sound continuously until the STOP button is 
pressed, or the loading door is opened. 
7. Safety Tumble, Display Count, or Pay: If DIP 
switch #1 is set for OPL, then DIP switch #7 in 
the ON position enables the safety tumble. If DIP 
switch #1 is set for Coin, then DIP switch #7 in 
the display of “PAy,” to indicate that coins are 
needed to run the tumbler. 
8. Programming: This switch enables or disables 
the programming feature and should normally be 
in the OFF position.
Function
OPL
Coin
1
Tumbler Type
OFF
ON
OPL=Off; Coin=On
2
Temperature Units
OFF
OFF
ºF=Off; ºC=On
3
Local/Remote 
Reversing
ON
ON
Local=On; Remote=Off
4
Empty
ON
ON
Always ON
5
Empty
ON
ON
Always ON
6
Buzzer Timer
ON
ON
5 Sec=Off; Continuous=On
7
Safety Tumble (OPL) 
or Coin Count/Pay 
(Coin)
ON
OFF
#1
#7
DIP SWITCH
OFF
ON
SAFETY TUMBLE
OFF
OFF
NO SAFETY TUMBLE
ON
ON
COIN COUNT
ON
OFF
PAY
8
Programming
OFF
OFF
Disable=Off; Enable=On
Table 2