Alliance Laundry Systems 70400301r3 Manual Do Utilizador

Página de 30
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Operating Instructions
17
70400301
DMP Coin Features
Coin Keypad Interface
- START button to start or resume a cycle.
- TEMP button to select HIGH, MEDIUM, or LOW 
temperature. 
- Two hidden buttons to increment or decrement the 
programmable time and temperature options. 
Power-Up
Upon applying power to the tumbler, the display will 
show “PAy” and the DRYING and COOLING LEDs 
will be off until coins are deposited to increase the 
tumbler run time. When time is displayed, the default 
(LOW) temperature setting LED will be on until a 
different temperature setting is selected. 
Power Failure
If a power loss occurs during operation, a cycle will 
not resume until the START button is pressed. To 
cancel the remaining cycle, press the internal CLEAR 
button.
Coin Operation
The tumbler run time is determined by the pre-
programmed run time per coin and the number of 
coins deposited into the tumbler. The maximum time 
that can be accumulated and displayed is 99 minutes. 
The drying time is the difference between the run time 
and the cooling time. The cooling time is pre-
programmed to be 2 to 5 minutes. The drying 
temperature can be selected from LOW, MEDIUM, or 
HIGH temperature settings by pressing the TEMP 
button. 
Coin Programming
The Coin board programming mode can only be 
entered when “PAy” is displayed. DIP switch #7 must 
be in the OFF position.
Programming is enabled by setting DIP switch #8 to 
the ON position. 
The programming mode is entered by pressing and 
holding the CLEAR button for three seconds.
The programming follows the following parameter 
order:
1. Tumbler run time per coin (DRYING), 
COOLING time, HIGH temperature setpoint, 
MEDIUM temperature setpoint, LOW 
temperature setpoint.
2. An LED will be on to indicate which parameter is 
flashing on the display. 
3. The hidden front panel increment and decrement 
keys are used to change the value.
4. The CLEAR button is used to recall the default 
value. 
5. The START button is used to step to the next 
parameter.
6. After the last parameter, “End” will be flashing.
7. Press the START button one last time to store the 
settings and exit the program mode.
8. “PAy” will be displayed.
9. If it is determined that the data did not program 
correctly, the error message “E2F” will flash for 
4 seconds, and then the default coin parameters 
will be used. 
The tumbler run time per coin is programmable for 1 
to 20 minutes with the default preset to 10 minutes. 
The cooling run time is programmable from 2 to 
5 minutes with the default preset to 2 minutes.
The three temperatures setpoints are programmable for 
100ºF (38ºC) to 185º/195ºF (85º/90ºC) with the 
following default settings:
- HIGH equal to 185ºF (85ºC)
- MEDIUM equal to 150ºF (66ºC)
- LOW equal to 135ºF (57ºC)
Stop
When in the Coin mode, the tumbler will stop if the 
tumbler door is opened while the tumbler is running. If 
the CLEAR button, located behind the board, is 
pressed, the tumbler will stop, the tumbler time will be 
zeroed and the display will show “PAy.”
Coin Count
The unit will count the number of coins deposited.
Setting DIP switch #7 to the ON position will display 
the coin count since it was the last reset. 
To reset the count, press the CLEAR button and “00” 
will be displayed. 
If the coin count is greater than “999,” the display will 
flash “999.” 
Setting DIP switch #7 to the OFF position will return 
the display to “PAy.”