Thermador C272 Manual Do Utilizador

Página de 8
Page 2
The cabinet cutout dimensions for wall mounted and
under the counter installations are shown in Figs. 2 and
3, respectively.
It is good practice, when oven is installed at the end of
a cabinet run, adjacent to a perpendicular wall or cabinet
door, to allow at least 1/4" space between the side of the
oven door and the wall/door.
Wall Mounted Units —
For oven support, install 2 x 4’s extending front to back
flush with the bottom and the side of the opening.
The supporting base must be well secured to the floor/
cabinet and level with the floor line.
Cut the bands from the carton.  Carefully remove the
carton, fillers and all packing material.  Included with
your new Thermador oven are the following:
Number of Racks Per Oven Model
C272 / C302 / CM302
6
SCD272 / SCD302
6
SC272 / SC302
5
S272 / S302 / CJ302
4
SC301 / C271 / C301 / CM301 / SMW272 / SM272
3
S301
2
One 2-Piece Broiler Pan
Care & Use Manual
Installation Instructions
Bottom Trim
Installation Screws (Packet)
Quick Guide
Cookbook (C, CJ and CM models only)
Remove Screws -
4 places
Fig. 1  Oven Base Attachment
The bottom trim is shipped, wrapped in waxed paper, on
top of the unit and should not be unpacked until the final
step when the oven has been placed in the cabinet. See
Fig. 6.
STEP 2: CABINET  PREPARATION
STEP 1: UNPACKING
TABLE OF CONTENTS
STEP 1: UNPACKING ............................................................................................ 2
STEP 2: CABINET PREPARATION ..................................................................... 2
STEP 3: ELECTRICAL INSTALLATION ............................................................. 6
STEP 4: INSTALLING THE OVEN ...................................................................... 7
STEP 5: INSTALLING THE BOTTOM TRIM .................................................... 8
NOTE:  The conduit box for double ovens (S272,
SC272, SCD272, S302, SC302, SCD302, C272, C302,
CM302, CJ302, SMW272 and SM272) should be located
above the unit to facilitate connecting and servicing.  For
single ovens (S301, SC301, C271, C301 and CM301) the
conduit box may be installed either above or below the
unit.  If the conduit box is installed below the unit, a 2"
diameter hole or space is required between the back wall
and the right rear of the 2 x 4 supports.  See Fig. 2
When an oven is installed, the cabinet base must be
capable of supporting the oven weight as listed below:
Oven
Pounds
Kilograms
S-series Single Oven
165
75
C-series Single Oven
210
95
CM Single Oven
240
109
S-series Double Oven
330
150
C-series Double Oven
355
161
CM/CJ Double Oven
370
168
Shipping base skid