Phihong POE60U-560G Manual Do Utilizador
POE60U-560(G)-XX-R Characteristics
WWW.PHIHONG.COM
INPUT:
AC Input Voltage Range
AC Input Voltage Range
90 to 264VAC
AC Input Voltage Rating
100 to 240VAC, 47-63Hz
AC Input Current
2A (RMS) maximum for 90VAC
1.2A (RMS) maximum for 240VAC
1.2A (RMS) maximum for 240VAC
Leakage Current
3.5mA maximum @ 254VAC 60Hz
AC Inrush Current
30A (RMS) maximum for 115VAC
40A (RMS) maximum for 230VAC
40A (RMS) maximum for 230VAC
OUTPUT:
Total Output Power
60W
DC Offset
No data degradation with DC imbalance 18mA per
min.
min.
Efficiency
75% (typical) at maximum load, and 120VAC 60Hz
Hold-up Time
10mS minimum 120VAC and maximum load
Transient O/P Voltage Protection
60V maximum
ENVIRONMENTAL:
Temperature
Operation
0 to +40°C
Non-operation
-25 to +65°C
Humidity
Operation
5 to 90%
EMC
FCC Part 15 Class B
EN55022 Class B
EN55022 Class B
Isolation Test
Primary to Secondary: 4242VDC for 1 minute 10mA
Primary to Field Ground: 2121VDC for 1 minute
Output to Field Ground: 2121VDC
Primary to Field Ground: 2121VDC for 1 minute
Output to Field Ground: 2121VDC
Immunity
ESD:
EN61000-4-2. Level 3
RS:
EN61000-4-3. Level 2
EFT:
EN61000-4-4. Level 2
Surge:
EN61000-4-5. Level 3
CS:
EN61000-4-6. Level 2
Voltage Dips
EN61000-4-11
Harmonic:
EN61000-3-2 Class A
Insulation Resistance
Primary to secondary: >10M OHM 500VDC
Primary to FC: >10M OHM 500VDC
Primary to FC: >10M OHM 500VDC
IEEE 802.3af/at Interoperability
If 25kohm is detected the unit operates in
“IEEE802.3at mode” 30W 2 pair powering. 12.5k
detection resistance required for full power
UNH Interoperability report available upon request
“IEEE802.3at mode” 30W 2 pair powering. 12.5k
detection resistance required for full power
UNH Interoperability report available upon request
FEATURE:
Detection
Same as IEEE802.3af and IEEE802.3at, it will power
2 pairs at 30 Watts; 12.5kohm detection resistor value
required to turn on full power 4 pair power. VC Model
has 25Kohm detection resister value requirement to
turn on full 4 pair power.
2 pairs at 30 Watts; 12.5kohm detection resistor value
required to turn on full power 4 pair power. VC Model
has 25Kohm detection resister value requirement to
turn on full 4 pair power.
Over Voltage/Current, Short Circuit
Protection
Outputs equipped with short circuit protection and
overload protection as per 802.3af specifications
except max average current is 0.55A, Peak 0.6A per
pair. The output can be shorted permanently
without damage
overload protection as per 802.3af specifications
except max average current is 0.55A, Peak 0.6A per
pair. The output can be shorted permanently
without damage
Indicators
Green LED 1: DC Power “OK”
Red LED: Fault detected
Solid Green LED 2: Power detected “CONNECT”
at 75W
Flashing Green LED 2: IEEE802.3at detected
“CONNECT” at 30W
Red LED: Fault detected
Solid Green LED 2: Power detected “CONNECT”
at 75W
Flashing Green LED 2: IEEE802.3at detected
“CONNECT” at 30W
Input Connector
IEC320 inlet 3 pin