Alto-Shaam 500-th-iii Manual Do Utilizador

Página de 49
 
TH/III 
InsTallaTIon
/
operaTIon
/
servIce
 
manual
 
pg
. 29
S E R V I c E
    d A N g E R
dIScONNEcT UNIT FROM 
pOwER SOURcE BEFORE 
cLEANINg OR SERVIcINg.
N O T E
If the appliance has been unplugged for an 
extended period of time, the Real Time Clock may 
require recharging.  Turn main breaker to the unit 
off for 10 seconds and then restore power.  
For more information, see Error Code E-60 in 
the Troubleshooting section of this manual.
c A U T I O N
THiS SECTiON iS PROViDED FOR THE ASSiSTANCE 
OF QUALiFiED SERViCE TECHNiCiANS ONLY AND 
iS NOT iNTENDED FOR USE BY UNTRAiNED OR 
UNAUTHORiZED SERViCE PERSONNEL.
A.  No power.  display will not light.
 
1.   Verify that power is available at the outlet or junction box.
 
2.   Verify that the circuit breaker switch on the back of the unit is turned on.
 
3.   Verify that the power cord is not open.  Check continuity with a VOM meter.
 
4.   If the problem persists, call a qualified Alto-Shaam service technician at 1-800-558-8744.
B.   display is lit but unit is not heating. 
 
 Check to verify that the high limit switch located at the rear of the unit top has not been  
tripped.  If it has been tripped, reset by pressing in the hi-limit reset button at the rear  
of the oven.
  
 After resetting, the cause of the high limit trip must be corrected.  If the high limit switch  
will not reset, the high limit switch is defective and must be replaced.  
This is a safety  
device and must not be bypassed or removed from the circuit.
c.  To test air sensor: 
 
 Test air sensor by placing sensor in ice water bath and using an ohmmeter set on the ohm scale.   
The reading should be 100 ohms resistance.  If it is more than 2 ohms higher or lower, sensor  
needs to be replaced. 
d.  To test probe sensor: 
 
 Test food probe by placing in ice water bath and using an ohmmeter set on the ohm scale.   
The reading should be 100 ohms resistance.
TROUBLE ShOOTINg INTERNAL ELEcTRIcAL cOMpONENTS
    d A N g E R
LOcK-OUT OR pOST 
BREAKER pANEL UNTIL 
SERVIcE wORK hAS 
BEEN cOMpLETEd.   
This section is provided for the assistance of qualified technicians only and is not intended for use by untrained 
or unauthorized service personnel.  If your Alto-Shaam
®
 unit is not operating properly, check the following before 
calling your Authorized Alto-Shaam Service Agent:
☛ 
 
 
Check main power circuit breaker to the unit and verify that the circuit breaker on the back of the unit is turned 
on, if applicable. 
 
 
Do not attempt to repair or service the unit beyond this point.  Contact alto-Shaam for the nearest authorized 
service agent.  repairs made by any other service agents without prior authorization by alto-Shaam
®
 will 