Alliance Laundry Systems 25 pound capacity Manual Do Utilizador

Página de 29
Operating Instructions
11
70400001
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Figure 4 
Single Drop Control
SD and SX Control Suffixes
1. Select HIGH, MED, LOW or NO HEAT by 
turning the temperature knob.
HIGH temperature 190° F (87° C)
MED temperature 160° F (71° C)
LOW temperature 130° F (54° C)
2. Insert the coin(s) in the coin slot.
3. Press START button to start tumbler.
IMPORTANT: To stop the tumbler at any time 
during the cycle, OPEN DOOR. To restart the 
tumbler, CLOSE door and press START button.
NOTE: If display show an error code, refer to 
Error Codes
 section.
4. When the cycle is complete, open door and 
remove the laundry.
NOTE: This machine includes an extended tumble 
feature. Starting 20 minutes after a cycle ends, the 
cylinder will tumble for two minutes every hour 
without heat, up to 18 hours or until door is 
opened.
Preliminary Control Information
Power-Up Mode
When power is applied to the tumbler the control will 
enter Ready Mode, unless a cycle was in process prior 
to a disruption of power. If a power disruption is less 
than 5 seconds, with a cycle in process, the control will 
enter Run Mode once power is restored and continue 
the cycle. If a power disruption is more than 5 seconds, 
with a cycle in process, the control will enter Start 
Mode once power is restored.
If the dry time dipswitch settings have not changed 
from the factory default, the IN USE LED will flash 
two to five times, depending on model.
Ready Mode
In Ready Mode, the control waits for the vend to be 
satisfied before entering Start Mode.
Start Mode
In Start Mode, the vend has been satisfied, but the 
Start button has not been pressed. The IN USE LED 
will be lit. The timer will not count down until the 
Start button is pressed.
Run Mode
In Run Mode, the control is running a cycle. The IN 
USE
 LED is lit.
TMB2123N