Using the LCD Menu
21
Model 3231 User Manual 
2 • Initial Configuration
G.SHDSL
LAN
CPE Config
Use this menu on the CO unit to configure the CPE unit. 
(None of the items in this menu may be configured if this unit is set as the CPE).
Table 4. G.SHDSL Menu Options
Submenu
Options
Line Rate
192 kbps – 4608 kbps
I-bits
0 – 7
Mode
CO or CPE
Annex
A or B
Transmit Gain
-1.6 dB – 1.6 dB
Eth Link Kill
Enabled or Disabled
If enabled, the Ethernet link will go down if the DSL link goes down.
Noise Margin
View the noise margin in dB. (This option is not configurable).
Restart DSL
Reconfigure DSL and retrain link.
This must be selected after any of the G.SHDSL options are changed (except Eth 
Link Kill, which takes effect immediately).
Table 5. LAN Menu Options
Submenu
Options
IP Address
Set and modify the LAN IP address
Netmask
Set and modify the LAN netmask
Default GW
Set to 000.000.000.000 to remove the default gateway
Table 6. CPE Config Menu Options
Submenu
Options
CPE Cfg State
Wait until this state reaches Idle before configuring any of the CPE 
options.
 This may take 1-2 minutes after the DSL link comes up. Any changes to 
the CPE options that are made before reaching the Idle state will be lost.
CPE Line Rate
192 kbps – 4608 kbps
CPE IP Address
Set and modify the CPE IP address
CPE Netmask
Set and modify the CPE netmask
CPE Default GW
Set to 000.000.000.000 to remove the CPE’s default gateway
Get CPE Config
Request the CPE to report its configuration to this unit. 
This is unnecessary because the CO will always reuqest the CPE’s configuration 
when the link comes up.
Set CPE Config
Send new configuration to the CPE.
This must be selected after changing any of the parameters in this menu.