STATUS LEDs 
Description 
Action 
1, 4 
The operator is trying to register a 
handset or place an admin call on an 
MCU with no phone lines. 
Return mode switch to the NORMAL 
position. 
2, 4 
The MCU was powered on with the 
mode switch in the wrong position. 
Turn off the MCU, place the mode switch to 
the NORMAL position and turn back on. 
3, 4 
Configurations on a multi-MCU 
installation do not match in each of 
the units.  
Most likely to occur when an MCU 
was just added to the system. 
Erase the configuration in the MCU with 
incorrect configuration definitions (probably 
the MCU that was just added.) To erase the 
configuration, refer to Chapter 8, section 
Replace an MCU.
 
Not
e:
 Do not erase the configurations in all 
the MCUs. In multiple MCU installations the 
handset registration information is shared 
among the MCUs. This allows you to 
replace an MCU without re-registering all 
the handsets. 
1, 3, 4 
REGISTER or ADMIN mode selected on 
more than one MCU at the same 
time. 
Only one mode switch can be in ADMIN or 
REGISTER at a time. Check the MCUs and 
take one of them out of REGISTER or ADMIN 
mode.  
2, 3, 4 
The MCU was powered on with the 
mode switch in the wrong position. 
Turn off the unit, place the mode switch to 
the NORMAL position and turn back on. 
1, 2, 3, 4 
Internal problem with the MCU. 
Contact Polycom Customer Service for 
technical support. 
1, 5 
The MCU was powered on with the 
mode switch in the wrong position. 
A possible Base Station failure has 
been detected. A Base Station that 
had previously been heard by another 
Base Station can no longer be heard. 
Turn off the MCU, place the mode switch in 
the NORMAL position and turn back on.. 
Check to see if the system was powered on 
with the switch in the wrong position. If not, 
contact Polycom Customer Service. 
The MCU was powered on with the 
mode switch in the wrong position. 
One or more of the Base Stations on 
this unit is disabled because it is 
located too close to other Base 
Stations. The ERROR display refers to 
the LED that is red. If more than one 
LED is red, it refers to the lowest 
numbered Base Station. 
Turn off the MCU, place the mode switch in 
the NORMAL position and turn back on. 
Identify which Base Station has been 
disabled and move it away from its nearest 
neighbor Base Station 
 
If Mode switch is in ADMIN mode: 
Adjust the companding mode from Mu law 
to A law. Refer to Chapter 11, section 
Change Companding
 
3, 5 
The MCUs have incompatible 
versions of software. 
Contact Polycom Customer Service for 
technical support.