Lowrance electronic globalmap baja 840c Manual Do Utilizador

Página de 164
135 
appear: Do you wish to re-calibrate the device? 
7. Highlight 
N
O
 and press 
ENT
.  
8. Take your vessel out on the water and burn at least five gallons of 
fuel. Be sure you run only ONE engine — the engine connected 
to your fuel flow.
  
9. Fill up your tank again, noting how much fuel you added to the tank. 
Compare that number to the Fuel Used figure displayed on the page 
you customized. If the amount of fuel you added to the tank and the 
fuel used figure are off by more than 3 percent, we recommend the fuel 
flow be calibrated. 
NOTE
You must use the gauge's Fill Tank command when filling your fuel 
tank to keep the fuel flow updated with correct information on the 
amount of fuel in the tank. 
To calibrate an EP-10 Fuel Flow: 
10. If calibration is necessary, press 
MENU
|
MENU
, select
 NMEA
 
2000
 and 
press 
ENT
11. Highlight 
F
UEL 
M
ANAGEMENT
 and press 
ENT
.  
12. Select 
T
ANK 
L
OCATION
 and press 
ENT
 to choose the location of the tank 
connected to selected fuel flow. Press 
ENT
13. Highlight 
F
ILL 
T
ANK
 and press 
ENT
. The following message will ap-
pear: Are you sure you wish to Fill Tank? Select 
Y
ES
 and press 
ENT
14. The following message will appear: Do you wish to re-calibrate the 
device? S
elect 
Y
ES
 and press 
ENT
.  
15. Repeat these steps for each EP-10 Fuel Flow you want to calibrate. 
To Reset Calibration: 
1. Press 
MENU
|
MENU
, select
 NMEA
 
2000
 and press 
ENT
2. Highlight 
F
UEL 
M
ANAGEMENT
 and press 
ENT
.  
3. Highlight 
E
NGINE 
S
ELECT
 and press 
ENT
. The Engine Select menu will 
appear with up to four options: All Engines, Port, Center and Star-
board. Selecting All Engines will reset calibration for all engines back 
to factory defaults. 
4. Select All Engines or the engine connected to the desired device and 
press 
ENT
.  
5. Highlight 
R
ESET 
C
ALIBRATION
 and press 
ENT
. The following message 
will appear: Are you sure you wish to Reset Calibration?