Directed Electronics rk20 Manual Do Utilizador

Página de 56
43
© 2008 Directed Electronics. All rights reserved.
Feature descriptions
The features of the system are described below. Default settings are in bold. The 
numbers in parentheses indicate the number of times the Status LED flashes.
 Menu 1
1-1 Horn Honk Pulses OFF: (1) No audible confirmation on Lock or Unlock. 
(2) 20ms horn honk, (3) 30ms horn honk, (4) 40ms horn honk, (5) 50ms horn 
honk
1-2 Ignition Locks OFF/ON : (2) When turned on Locks the doors three seconds 
after  the  ignition  is  turned  On  and  the  vehicles  doors  are  closed.  (1)  When 
turned Off the system does not lock the doors when the ignition is turned on.
1-3 Ignition Unlocks OFF: (2) Unlock: When turned On Unlocks the doors when 
the ignition is turned off. (1) When turned Off the system does not unlock the 
doors when the ignition is turned off.
1-4 0.8 sec Door Lock Pulse (1)Duration: The default setting is 0.8 second door 
lock pulses. Some European vehicles, such as Mercedes-Benz and Audi, require 
longer lock and unlock pulses to operate the vacuum pump. Programming the 
system to provide 3.5 second (2) pulses, accommodates the door lock interface 
in these vehicles. (See door lock connections section for wiring information re-
garding Type E door locks interfacing. The 0.4 second (3) pulse is required on 
some vehicles where the lock wires can also control the windows and the 0.8 
second pulse causes the windows to open/close when locking or unlocking. 
1-5 Single Pulse Unlock (1): The system sends out a single pulse when unlock-
ing. (2) Double-pulse unlock sends out 2 pulses when unlocking.
1-6 Single Pulse Lock (1): The system sends out a single pulse when locking. (2) 
Double-pulse lock sends out 2 pulses when locking.