Diagnostic Indicator Display  
 
There is a two-digit error code display located under horizontal output window near the Metrologic logo on the platter (see 
figure below).   
 
 
Figure 30.  Error Code Display (Optional Product Roll Bar Shown) 
 
 
 
The following is a list of possible error codes and their meanings.  Some errors will require immediate scanner maintenance. 
 
E
RROR 
C
ODE
 
D
ESCRIPTION
 
01 Reserved 
 
02 
RAM ERROR – The scanner’s Random Access Memory (RAM) is tested as faulty.  Return the unit for repair at an 
authorized service center. 
03 
PROGRAM ERROR – The scanner’s software program is failing.  Return the unit for repair. 
04 
INTERFACE ERROR – After power up and any application exit (e.g. MetroSet, etc.), the scanner checks the 
interface hardware with that chosen in configuration.  If they do not agree, an interface error exists.  Correct this 
problem by getting the proper hardware interface OR programming StratosS configuration for the proper interface 
hardware attached. 
05 
CONFIGURATION ERROR – The non-volatile configuration memory did not agree with the data last saved.  
Default configuration data is then used and the scanner continues operating.  This error is also accompanied by 3 
beeps.  This error will remain during operation as a reminder that this power cycle is scanning against a default-
generated configuration.