Figure 3. StratosS Calibration Seal and Switch Location
 
 
5.  Disconnect the scale-to-host RS232 cable from the unit (dual cable 
interface only.) 
 
 
 
Figure 4. Disconnect scale-to-host RS232 Cable
 
 
6.  Reinstall the platter and connect AC power to the scanner.   
 
Check the AC input requirements of the power supply to make sure the voltage matches 
the AC outlet.  The outlet should be located near the equipment and be easily 
accessible. 
 
Metrologic recommends using a switched AC outlet.  The switch should be located on 
the operator’s side of the checkout counter in close proximity to the scanner/scale to 
facilitate calibration and service of the unit. 
 
 
To maintain compliance with applicable standards, all circuits connected to the scanner 
must meet the requirements for SELV (Safety Extra Low Voltage) according to EN/IEC 
60950-1.  
 
 
To maintain compliance with standard CSA C22.2 No. 60950-1/UL 60950-1 and norm 
EN/IEC 60950-1, the power source should meet applicable performance requirements 
for a limited power source.