Metrologic Instruments stratos ms2xxx series Manual Do Utilizador

Página de 88
 
 
77 
S
CANNER 
T
EST 
B
AR 
C
ODES
 
 
Supplemental Tests 
 
Display Software Numbers  
 
The following codes do not require that the MS2xx0 to be in scale 
program mode. 
 
These codes are for test purposes only. 
 
The following code will display software #’s on the 2-digit diagnostic display.  The 
lasers will be turned off while the numbers are being displayed.  The first number 
is the main decode processor software number.  The second number is the I/O 
processor’s software number.  Since only 2 digits can be displayed at a time, the 
following sequence is used as an example of what may be observed: 
 
2-Digit 
Display 
 
Description of each sequentially displayed sets of digits. 
(Example shown will represent: ‘ 15269’   ‘ 15138’) 
x  1 
The first digit of the five main decode processor software number 
appears right justified. 
5  2 
The second and third digits. 
6  9 
The forth and fifth digits. 
x x 
Pause before next set of numbers. 
x  1 
The first digit of the five digit I/O processor software number 
appears right justified. 
5  1 
The second and third digits. 
3  8 
The forth and fifth digits. 
  x  =  Blank / No Digit Displayed 
 
After the last sets of digits are displayed, the scanner resumes scanning 
operation.  If the current interface does not use an I/O processor, the software 
number may appear ‘ 0  00  00’.  This capability exists in software 15269 and 
later. 
 
Display Software Number 
³
9
9
8
0
6
2