Dacor ER48D Manual Do Utilizador
PLANNING
GUIDE
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
5.16
Epicure
®
Ranges
ER36D, ER48D
2/2
CUT-OUT DIMENSIONS
Range Model
“F”
“G”
“H”
ER36D
42” (1067mm)*
36” (914mm)**
36 1/16”
(916mm)**
33 1/2”
(848mm)
ER48D
54” (1372mm)*
48” (1219mm)**
48 1/16”
(1221mm)**
43 1/2”
(1102mm)
* Recommended
**Minimum
Gas and Electrical Service
For replacement purposes, the location of the existing utilities
◊
may be utilized provided they do not interfere with the sides or
rear of the range. Check local building codes for permissible
locations.
An external manual shut-off valve must be installed between
An external manual shut-off valve must be installed between
◊
the gas inlet and the range, for the purpose of turning on or
shutting off gas to the appliance.
The installation must allow for the following:
Access to the gas shut-off valve when the unit is installed.
◊
Access to the remote circuit breaker panel/fuse box, when the
◊
range is in place.
The gas supply piping and shut-off valve, and the electrical
The gas supply piping and shut-off valve, and the electrical
◊
junction box/receptacle must be located so they do not
interfere with the range when it is installed.
The junction box and gas shut off valve must be located so
The junction box and gas shut off valve must be located so
◊
that the range can be pulled out for service while the appliance
remains connected.
Revised
03/10/09
3
2, 5
F
G
3
Cabinet/countertop depth is at discretion of customer but
cabinet face MUST NOT protrude further than rear of front
panel, see product dimensions.
4
Consult local code for exact location requirements.
5
Not applicable for cabinets more than a horizontal
distance of 10” (254mm) from the edge of the range.
1
Vertical to combustibles directly above cooking surface;
if installing an overhead vent hood, also check the hood
specifications for minimum required clearances.
2
Measured from range top panel.
Non-combustible
surface along
back wall
recommended
30” (762mm)
Min.
1
36 1/2”
(927mm)
Max.
13” (330mm)
Max.
5
Suggested
location of
utilities
4
G
10" (254 mm) Min.
to combustible side
walls above the range
(both sides)
to combustible side
walls above the range
(both sides)
non-combustible
Minumum Countertop Height:
30 1/4” (768 mm)
Maximum Countertop Height:
36 1/2” (927 mm)
rear wall recommended
Backsplash
3/8" (10 mm)
Min. flat countertop
overhang
H
2 13/16"
(71.4 mm)
3
CUtoUt wIth oPtIoNAL ERv RAIsED vENt
(toP vIEw)
APPROVED RAISED VENT MODELS
Raised Vent Model
For use with
Range Model
ERV36-ER
ER36D
ERV48-ER
ER48D
Stiffener
Cabinet face**
Countertop*
*
IMPORTANT: See “CUTOUT WITH OPTIONAL ERV RAISED VENT”
for countertop cutout dimensions.
**
IMPORTANT: Cabinet face must not stick out further than
back of control panel.
Back of
control
panel
ERV36-ER or
ERV48-ER
raised vent
ER36D or ER48D Range
3/8” Min. (10 mm)
space behind
raised vent
chassis to clear
stiffener
3/8” Min. (10 mm)
flat countertop overhang
required behind cutout
Countertop height:
30 1/4" (768 mm) Min.
36 1/2” (927 mm) Max.
RAIsED vENt INstALLAtIoN sIDE vIEw
Tolerances: +1/16”, -0, (+1.6mm, -0) unless otherwise stated