38
©
2006 
Directed Electronics
System Status Chirps
Table of Zones
NOTE: The Warn Away
®
response does not report on the LED.
Zone No.
Trigger type
Input description
1
Instant
H1/7 BLUE wire. Connect to optional hood/trunk
pins.
2
Multiplexed
For the onboard shock sensor light impacts 
will trigger a Warning Zone response, while 
heavy impacts will instantly trigger the full alarm
sequence.
3
Instant Two-stage, or constant
Door switch circuit. H1/8 GREEN or H1/6 VIOLET.
4
Multiplexed Input
Inputs shorter than 0.8 seconds will trigger a 
Warning Zone response, while inputs longer than
0.8 seconds will instantly trigger the full alarm 
sequence.
5
Two-stage (similar to doors)
Ignition input. H1/4 YELLOW.
6
Hood trigger
H2/2 GREY
7
Multiplexed input (sensors)
Inputs shorter than 0.8 seconds will trigger a 
Warning Zone response, while inputs longer than
0.8 seconds will instantly trigger the full alarm 
sequence.
Action
Number of Chirps
Description
Arm
1
System armed
Arm
1 (3 second delay), 1
System armed with Bypass Notification 
Disarm
2
System disarmed
Disarm
4
System disarmed with Tamper Alert
Disarm
5
System disarmed NPC
®
active