Heat & Glo  •  CFX-CRESCENT  •  705-900  Rev. P  •  12/07
35
Before lighting the fireplace, be sure to do the
following:
• Remove all paperwork from underneath the
fireplace.
Review safety warnings and cautions
• Read the Safety and Warning Information section
at the beginning of this Installers Guide.
Double-check for gas leaks
• Before lighting the fireplace, double-check the unit for
possible gas leaks.
Double-check vent terminations.
• Before lighting the fireplace, double-check the unit for
possible obstructions that could be blocking the vent
terminations.
Double-check for faulty components
• Any component that is found to be faulty MUST BE
replaced with an approved component. Tampering with
the fireplace components is DANGEROUS and voids
all warranties.
A small amount of air will be in the gas supply lines. When
first lighting the fireplace, it will take a few minutes for the
lines to purge themselves of this air. Once the purging is
complete, the fireplace will light and will operate normally.
Subsequent lightings of the fireplace will not require this
purging of air from the gas supply lines, unless the gas
valve has been turned to the OFF position
, in which
case the air would have to be purged.
NOTE: The fireplace should be run 3 to 4 hours on the
initial start-up. Turn it off and let it cool completely.
Remove and clean the glass. Replace the glass and run
the fireplace for an additional 8 hours. This will help to
cure the products used in the paint and logs.
Step 11
Before Lighting
the Fireplace
Step 12
Lighting
the Fireplace
After the
Installation
!
You’ve reviewed all safety warnings, you’ve checked the
fireplace for gas leaks, you know the vent system is
unobstructed, and you’ve checked for faulty components.
Now you’re ready to light the fireplace.
WARNING: PLEASE REFER TO THE USER’S
MANUAL FOR ALL CAUTIONS, SAFETY, AND
WARNING INFORMATION PERTAINING TO THE
LIGHTING AND OPERATION OF THE FIRE-
PLACE.
LEAVE THIS INSTALLATION MANUAL WITH
THE APPLIANCE FOR FUTURE REFERENCE.
During this break-in period it is recommended that some
windows in the house be opened for air circulation. This will
help avoid setting off smoke detectors, and help eliminate
any odors associated with the fireplace’s initial burning.