Kenwood TK-7160 Manual Do Utilizador

Página de 52
TK-7160
31
Receiver Section
1. Seisitivity
1) CH : RX low (Wide/Narrow)
SSG
ANT
Check
SINAD
CH : RX center (Wide/Narrow)
Oscilloscope
EXT. SP
: 12dB or higher
CH : RX high (Wide/Narrow)
AF V.M
2) SSG output
Distortion meter
: –118dBm (0.28
µV) (Wide)
: –116dBm (0.35
µV) (Narrow)
Mod : 1kHz
Dev : 
±3.0kHz (Wide)
Dev : 
±1.5kHz (Narrow)
2. Squelch 9 1) CH : RX low (Wide)
PC key
Adjust to open the squelch
CH : RX center (Wide/Narrow)
CH : RX high (Wide)
2) SSG output
: 12dB SINAD+7dB
Mod : 1kHz
Dev : 
±3.0kHz (Wide)
Dev : 
±1.5kHz (Narrow)
3. Squelch 1 1) CH : RX low (Wide)
CH : RX center (Wide/Narrow)
CH : RX high (Wide)
2) SSG output
: 12dB SINAD+2dB
Mod : 1kHz
Dev : 
±3.0kHz (Wide)
Dev : 
±1.5kHz (Narrow)
Item
Condition
Test equipment
Terminal
Parts
Method
Specifications/
Remarks
Measurement
Adjustment
ADJUSTMENT
Transmitter Section
1. Frequency 1) CH : TX center
Frequency counter
ANT
PC key
Adjust to center frequency
Within 
±100Hz
2) Transmit
2. Maximum 1) CH : TX high
Power meter
VR1
28W
±1W
power
2) Transmit
limitting
Item
Condition
Test equipment
Terminal
Parts
Method
Specifications/
Remarks
Measurement
Adjustment
4. RF
1) CH : RX center (Wide)
Tra generator
ANT
PC key
Adjust the BPF waveform
bandpass
CH : RX low (Wide)
Spectrum analyzer
BPF
to Fig. 1
filter
CH : RX high (Wide)
2) Tra generator output : –30dBm
Connect the spectrum analyzer
to BPF terminal
* Adjustment of TX VCO lock voltage
1. Remove R517, F501, R519 and R526 (all on component side).
2. Remove PCB from chassis.
3. Transmit and check voltage at [CV] point.
Warning : Do not transmit if step “1.” is not complete.
4. Adjust of voltage can be done by tuning TC442.
Item
Condition
Test equipment
Terminal
Parts
Method
Specifications/
Remarks
Measurement
Adjustment