Connect Tech titan-cpci Manual Do Utilizador

Página de 34
Titan/cPCI User’s Manual, Connect Tech Inc. 
28  
Revision 
1.01 
 
 
Example 
The following example shows the settings on JA, JB, JC and JD 
where port 1 is terminated on RTS ± and TxD 
±, the 
RS-422/485 port 2 is set for bias/termination on RTS 
±, TxD ±
CTS 
±, and RxD ±, the RS-422/485 port 3 is not terminated, 
and port 4 is set for RS-232 and therefore should not be 
terminated
 
 
JA 
JB 
JC 
1
2
3
4
5
6
7
8
JD 
1
2
3
4
5
6
7
8
Port 1 
Port 2 
Port 3
Port 4
Jumper Legend 
 
1 = RS-232/RS-422/485 
select 
2 = RS-422/485 half 
duplex mode control 
3 = RTS +/- termination 
4 = TxD +/- termination 
5 = CTS +/- termination 
6 = CTS +/- termination 
7 = RxD +/- termination 
8 = RxD +/- termination 
 
 
Technical Notes: 
1.  For full duplex, half duplex and multi-drop slave you can 
jumper position 2 on the jumper block. 
2.  For RS-232 port jumper position 1 on the jumper block.