omnitron-systems-technolo 10-100m Manual Do Utilizador

Página de 47
4.2
MODULE MANAGEMENT MODE
From the Module configuration screen, the management mode can be changed.  Select option 18 to change
the mode.  The management mode options will be displayed.
Module -  iConverter 10/100M
iConverter, Serial Agent
 Identifier -
Chassis Number
= 1
 Switch
ON Condition
OFF Condition
H/W
Actual
 Slot Number
= 1
1: Pause Enabled
Pause Disabled Off
Off
 Model Number
= 8919-0
2: Fiber HDX
Fiber FDX
Off
Off
3: UTP Manual
UTP Auto-Neg
Off
Off
 Serial Number
= xxxxxxxx
4: UTP 10 Mbps
UTP 100 Mbps
Off
Off
 Manufacturing Date = xxxxxxxx
5: UTP HDX
UTP FDX
Off
Off
 Product Revision
= x
6: Link Propagate
Link Segment
Off
Off
 Software Revision
= xx
7: Remote Fault
Normal
Off
Off
8: Symm Fault Det
Normal
Off
Off
 LED
9: BP A Enabled
BP A Disabled
On
On
 1: Power
= On
10: BP B Enabled
BP B Disabled
On
On
 2: Power Supply 1
= Off
11: Not Available
 3: Power Supply 2
= Off
12: Slave Only
Master/Slave    Off
Off
 4: Power Supply 3
= Off
13: Not Available
 5: Fiber Link
= Off
14: Not Available
 6: BP Master
= On
15: Not Available
 7: UTP 10  Link
= Off
16: Not Available
 8: UTP 100 Link
= Off
OAM settings:
 9: UTP FDX
= Off
17: IP Protocol State  On
18: Management Mode    Secure OAM
 Toggle Switch(1-16), (I)dentifier, (R)eset, (H)elp, (P)ortStat, Port(C)tl >
Mode (1=OAM Off, 2=Auto Secure OAM, 3=Auto ah OAM, 4=Secure OAM, 5=ah OAM): 3
The 10/100M module supports several management options.  Option 18 configures how the module will
communicate to its remote partner.  ‘Auto Secure OAM’ (option 2) and ‘Secure OAM’ (option 4) uses
Omnitron’s proprietary secure encrypted management channel.  ‘Auto Secure OAM’ will force the remote
partner to communicate using the Secure OAM protocol while ‘Secure OAM’ will only attempt to
communicate with the remote partner over the secure protocol.  The management channel can support IP or
IP-less connectivity based on the configuration of the ‘IP Protocol State’, option 17.  ‘Auto ah OAM’
(option 3) and ‘ah OAM’ (option 5)’ conforms to the IEEE 802.3ah specification.  ‘Auto ah OAM’ will
force the remote partner to communicate using the ah OAM protocol while ‘ah OAM’ will only attempt to
communicate with the remote partner over the ah protocol.  This option provides an industry standard
method of fault detection and monitoring.  The management channel supports both IP and IP-less connectivity
based on the configuration, option 17 and 18.
NOTE:  See NetOutlook User Manual for complete information on the management modes.