Hubbell euclid 4291 Manual Do Utilizador

Página de 4
4291
Hubbell Industrial Controls
Euclid™ Lifting Magnet Controller
Varistor Type Automatic Discharge
Specification 4291 • May 2004 • Replaces July 1990
General Information
The  Euclid Type  4291 Magnet Controller is 
for   use   with   all   types   and   makes   of   lifting 
magnets.  It assures fast and clean release of 
all types of magnet loads.
All or just part of the load may be dribbled, if 
desired.   In addition, because of the  circuit 
design, the magnet and magnet leads are not 
subjected to high induced voltages.
Automatically discharges magnet.
Fast and clean release of load.
Peak magnet induced voltage limited to un-
der 700 volts.
Wide reverse current adjustment for differ-
ent types of magnet loads.
Mechanically interlocked mill-type “Lift” and 
“Drop” contactors.
High-thermal capacity varistor discharge.
Permanently connected discharge path.
Discharge   path   completely   independent 
from the line.
“Drop”   contactor   opens   automatically   at 
end of drop cycle.
Front wired, front removable components.
Long contact life.
Minimum maintenance.
Full voltage reverse current.
NEMA 3R Enclosed
Application
Euclid Type 4291 Lifting Magnet Controllers 
have many uses from light scrap handling to 
extremely heavy plate or billet handling.  The 
flexibility of this magnet controller is illustrat-
ed by the ease of proper “cleaning” that can 
be   accomplished   when   switching   from   one 
type of material to another.  A simple adjust-
ment of the potentiometer (P1) is all that is 
necessary.  An inherent dribble characteristic 
is designed into each unit allowing material 
sorting   such   as  steel   plate  stacking,  by  re-
leasing one plate at a time.
Description
The Euclid Type 4291 Magnet Controller in-
corporates time proven components arranged 
to provide a new concept in magnet controller 
design and operation.
This controller includes all necessary power 
and reverse current contactors in addition to 
discharge path components.
Euclid’s   standard   mill-type   contactors   are 
used to carry the power to the magnet.  The 
reverse current or “Drop” contactor is also a 
mill-type contactor.  The commonly used dis-
charge resistor has been replaced by a high 
thermal capacity varistor connected in series 
with a silicon rectifier to assure a permanently 
connected independent discharge path at all 
times around the magnet.
Main power of “Lift” contactors, due to the cir-
cuit design described herein, need only Eu-
clid’s exclusive arc-centering, high-arc inter-
rupting system to handle the highly inductive 
magnet circuit.
The   high   thermal   capacity   of   the   nonlinear 
varistor   dissipates   the   energy   stored   in   the 
magnet   at   a   much   lower   value   of   induced 
voltage  than  does the  usual fixed   type  dis-
charge resistor.   The varistor assembly is a 
bank   of   silicon-carbide   composition   discs 
connected   in   parallel   and   cooled   by   alu-
minum radiating plates.
The maximum induced voltage permitted by 
the varistor is a peak of 700 volts.  This fea-
ture assures extra protection of the magnet 
and lead system insulation.  It also minimizes 
destructive arcing on the "Lift" contactor.
Non-linear   characteristics   of   the   varistor 
help   maintain   the   discharge   voltage   at   the 
maximum   allowable   voltage   until   all   of   the 
stored magnet energy is dissipated.  The Eu-
clid Type 4291 Magnet Controller dissipates 
stored energy as fast as any comparable de-
vice, but with a much lower induced voltage. 
It is not necessary to close the "Drop" contac-
tor immediately to provide a discharge path.
Full line voltage, for cleaning the magnet, is 
applied to the magnet terminals when the val-
ue of the induced magnet voltage declines to 
nearly the line voltage value.   Resistors are 
eliminated   from   the   reverse   current   circuit. 
This allows the reverse current to build up as 
fast  as the  magnet  inductive  characteristics 
will permit.
During the time of the stored energy dissipa-
tion, the reverse voltage across the magnet 
and the discharge varistor assembly signals 
the discharge Sensor Module (DSM) that the 
discharge cycle has begun.   When the dis-
charge voltage falls to 250 to 300 volts, the 
"DSM"   closes   a  pilot   Drop   Relay  (DR)   that 
energizes the Drop Contactor (D).
The adjustable time reverse current cycle be-
gins with the closing of the Drop Relay after 
practically   all   the   stored   magnet   energy   is 
dissipated   by   the   Discharge   Varistor   (DVA) 
assembly.  The DSM also controls the length 
of the reverse current cycle.   After a preset 
Page 1 of 4
Euclid Lifting Magnet Controllers Provide 3-Way Release of Load
Euclid Type 4291 automatic discharge type magnet controller is the only one on the market today that 
will assure (1) fast and clean release of full load, (2) accurate release of partial load and (3) precise 
control of dribbling.  It can be used with all types and makes of lifting magnets in any industrial applica-
tion.