Bard R-410A Manual Do Utilizador
Form No.
S3383-1112
Supersedes
S3383-510
Page
1 of 8
Air Conditioner Compressor:
Reciprocating compressors with
crankcase heaters are standard on 2,
2
Reciprocating compressors with
crankcase heaters are standard on 2,
2
½ and 3-ton models. Scroll
compressors are used on all other
models and no crankcase heaters
are required
models and no crankcase heaters
are required
.
R-410A Refrigerant:
Designed with R-410A (HFC) non-
ozone depleting refrigerant in
compliance with the Montreal protocol
and 2010 EPA requirements.
Designed with R-410A (HFC) non-
ozone depleting refrigerant in
compliance with the Montreal protocol
and 2010 EPA requirements.
ECM Indoor Blower Motor:
Features an electronically commutated
motor providing super-high efficiency,
low sound levels and soft-start
capabilities. The motor is self-
adjusting to provide the proper airflow
rate for a broad range of static
pressure in ducted installations without
user adjustment or wiring changes.
Features an electronically commutated
motor providing super-high efficiency,
low sound levels and soft-start
capabilities. The motor is self-
adjusting to provide the proper airflow
rate for a broad range of static
pressure in ducted installations without
user adjustment or wiring changes.
Aluminum Finned Copper Coils:
Grooved tubing and enhanced
louvered fin for maximum heat
transfer and energy efficiency.
Grooved tubing and enhanced
louvered fin for maximum heat
transfer and energy efficiency.
Outdoor coil is constructed with
special corrosion resistant
hydrophilic fin stock with 2-layer
coating. (1st layer - blue acrylic
primer; 2nd layer - clear topcoat.)
special corrosion resistant
hydrophilic fin stock with 2-layer
coating. (1st layer - blue acrylic
primer; 2nd layer - clear topcoat.)
Thermal Expansion Valves:
Models with reciprocating
compressors have bleed TXV,
models with scroll compressor have
non-bleed TXV.
Models with reciprocating
compressors have bleed TXV,
models with scroll compressor have
non-bleed TXV.
Discharge Muffler:
Standard on 2
Standard on 2
½ and 3-ton models.
Liquid Line Filter Drier:
Protects system against moisture.
Protects system against moisture.
Compressor Control Module:
Built-in off-delay timer adjustable from
30 seconds to 5 minutes. 2-minute
on-delay if power interrupt. 120-
second bypass for low pressure
control, and both soft and manual
lockouts for high and low pressure
controls. Alarm output for alarm relay.
Built-in off-delay timer adjustable from
30 seconds to 5 minutes. 2-minute
on-delay if power interrupt. 120-
second bypass for low pressure
control, and both soft and manual
lockouts for high and low pressure
controls. Alarm output for alarm relay.
Phase Rotation Monitor:
Standard on all 3-phase models.
Protects against reverse rotation if
power supply is not properly
connected.
Standard on all 3-phase models.
Protects against reverse rotation if
power supply is not properly
connected.
High & Low Pressure Switches are
Auto-Reset
Built-in lockout circuit resets from the
room thermostat. Provides commercial
quality protection to the compressor.
Auto-Reset
Built-in lockout circuit resets from the
room thermostat. Provides commercial
quality protection to the compressor.
Pre-Painted 20 Gauge Zinc Coated
Steel Cabinet:
Cleaned, rinsed, sealed and dried
before the polyurethane primer is
applied. The cabinet is handsomely
finished with a baked on textured
enamel, which allows it to withstand
1000 hours of salt spray tests per
ASTM B117-03.
Steel Cabinet:
Cleaned, rinsed, sealed and dried
before the polyurethane primer is
applied. The cabinet is handsomely
finished with a baked on textured
enamel, which allows it to withstand
1000 hours of salt spray tests per
ASTM B117-03.
Pre-Painted 16 Gauge Zinc Coated
Unit Base:
The unit base is treated with the
same paint coatings as the cabinet
above, insuring years of service.
Unit Base:
The unit base is treated with the
same paint coatings as the cabinet
above, insuring years of service.
Top Discharge Outdoor Fan:
Efficiently moves air quietly for
effective heat exchange.
Efficiently moves air quietly for
effective heat exchange.
Electrical Components & Controls:
Readily accessible for easier service.
Readily accessible for easier service.
G
REEN
R
EFRIGERANT
R-410A
PA13-SERIES PACKAGED AIR CONDITIONERS
Cooling Capacities:
23,000 to 56,000
SEER: 13.0
Standard Engineered Features
Field Installed Accessories
Optional Field Installed Electric Heat
Strips:
With automatic limit and thermal cutoff.
Strips:
With automatic limit and thermal cutoff.
• Field installed heater package for all
models.
• Features slide-in field assembly with
various BTUH outputs.
• Permits stocking of only one unit.
Optional Field Installed Low Ambient
Control:
Cycles outdoor fan motor below 55
Control:
Cycles outdoor fan motor below 55
°
F
outdoor temperature to maintain acceptable
condensing pressure.
condensing pressure.
• Intertek ETL Listed to Standard for Safety Heating
and Cooling Equipment ANSI/UL 1995/CSA 22.2
No. 236-05, Third Edition.
No. 236-05, Third Edition.
FRONT (INDOOR AIRFLOW) END OF UNIT
BACK (OUTDOOR AIRFLOW) END OF UNIT