Fujitsu MAX3036RC Manual Do Utilizador

Página de 94
Diagnostics and Maintenance 
6-4 
C141-E237 
b) 
When an error is detected in the hardware function test, the HDDs post the CHECK 
CONDITION status for all I/O operation request except the REQUEST SENSE command.  
The error status is not cleared even if the error information (sense data) is read.  Only when 
the power is turned off or re-turned on, the status can be cleared.  When this status is 
cleared, the HDDs execute the initial self-diagnostics again (see item (1)). 
 
Refer to Subsection 4.4.1 “SEND DIAGNOSTIC (1D)” of the Interface Specifications for further 
details of the command specifications. 
 
6.1.2 Test 
programs 
 
The basic operations of the HDDs themselves can be checked with the self-diagnostic function.  
However, to check general operations such as the host system and interface operations in a status 
similar to the normal operation status, a test program that runs on the host system must be used. 
 
The structure and functions of the test program depend on the user system requirements.  Generally, 
it is recommended to provide a general input/output test program that includes devices connected to 
the input/output devices on other I/O ports. 
 
Including the following test items in the test program is recommended to test the HDD functions 
generally. 
(1) Interface 
test 
 
The operations of the data buffer on the HDDs are checked with the WRITE BUFFER and READ 
BUFFER commands. 
 
(2) 
Basic operation test 
 
The basic operations of the HDDs are checked by executing self-diagnosis with the SEND 
DIAGNOSTIC command (see Subsection 6.1.1). 
 
(3) 
Random/sequential read test 
 
The positioning (seek) operation and read operation are tested in random access and sequential 
access modes with the READ, READ EXTENDED, or VERIFY command.