Kodak KAI-2093 Manual Do Utilizador
PRODUCT SUMMARY
KODAK KAI-2093 IMAGE SENSOR
1920 (H) X 1080 (V) PROGRESSIVE SCAN INTERLINE CCD IMAGE SENSOR
1920 (H) X 1080 (V) PROGRESSIVE SCAN INTERLINE CCD IMAGE SENSOR
DESCRIPTION
The KODAK KAI-2093 Image Sensor is a high-
performance multi-megapixel image sensor designed for
a wide range of medical imaging and machine vision
applications.
performance multi-megapixel image sensor designed for
a wide range of medical imaging and machine vision
applications.
The 7.4 µm square pixels with microlenses provide high
sensitivity and the large full well capacity results in high
dynamic range. The split horizontal register offers a
choice of single or dual output allowing either 15 or 30
frame per second (fps). The architecture allows for either
progressive scan or interlaced readout. The imager
features 5V clocking to facilitate camera design. The
vertical overflow drain structure provides antiblooming
protection, and enables electronic shuttering for precise
exposure control.
sensitivity and the large full well capacity results in high
dynamic range. The split horizontal register offers a
choice of single or dual output allowing either 15 or 30
frame per second (fps). The architecture allows for either
progressive scan or interlaced readout. The imager
features 5V clocking to facilitate camera design. The
vertical overflow drain structure provides antiblooming
protection, and enables electronic shuttering for precise
exposure control.
FEATURES
• Progressive scan (non-interlaced)
• HCCD and output amplifier capable of 40 MHz
• HCCD and output amplifier capable of 40 MHz
operation
• 5 V HCCD clocking
• Single or dual video output operation
• 28 light shielded reference columns per output
• Only 2 vertical CCD clocks and 2 horizontal CCD
• Single or dual video output operation
• 28 light shielded reference columns per output
• Only 2 vertical CCD clocks and 2 horizontal CCD
clocks
• Electronic shutter
• Low Dark Current
• Antiblooming protection
• Low Dark Current
• Antiblooming protection
APPLICATIONS
• Industrial Imaging
• Scientific Imaging
• Scientific Imaging
Parameter Typical
Value
Architecture
Interline CCD, Progressive
Scan or Interlaced Readout
Scan or Interlaced Readout
Total Number of Pixels
1984 (H) x 1092 (V)
Number of Effective Pixels
1928 (H) x 1084(V)
Number of Active Pixels
1920 (H) x 1080 (V)
Pixel Size
7.4 µm (H) x 7.4 µm (V)
Active Image Size
14.208 mm (H) x 7.992 mm (V)
16.3 mm (diagonal)
16.3 mm (diagonal)
Aspect Ratio
16:9
Number of Outputs
1 or 2
Saturation Signal
40,000 electrons
Output Sensitivity
14 µV/electron
Quantum Efficiency KAI-2093-ABA
(490 nm)
(490 nm)
40%
Quantum Efficiency KAI-2093-CBA
R(620 nm), G(540nm), B(460nm)
R(620 nm), G(540nm), B(460nm)
37%, 34%, 30%
Total Noise
40 electrons rms
Dark Current (Typical)
<0.5 nA/cm
2
Dynamic Range
60 dB
Blooming Suppression
100 X
Smear
<0.03%
Image Lag
<10 electrons
Frame Rate
Single Output, 20 MHz
Single Output, 35 MHz
Dual Outputs, 20 MHz
Dual Outputs, 37 MHz
9 fps
15 fps
17 fps
30 fps
Maximum Data Rate
40 MHz/Channel (2 channels)
Package
32 pin CERDIP
Cover Glass
Clear Glass or
Quartz Glass with AR Coating,
2 sides
Quartz Glass with AR Coating,
2 sides
Parameters above are specified at T = 40° C unless otherwise noted.
©Eastman Kodak Company, 2007
www.kodak.com/go/imagers
Revision 3.0 MTD/PS-0307