Vector compact elite vec010inv Manual Do Utilizador

Página de 15
10
W
W
W
WAA
A
ARRRRN
N
N
NIIIIN
N
N
NG
G
G
G!!!!
Do Not DC Charge for more than 3 Hours Maximum.
Do Not Leave Unattended while DC Charging.
5.
MAINTENANCE/REPLACEMENT PARTS
For replacement parts (bulbs, batteries, charging adapters, etc.), contact Vector Technical
Support: (954) 584-4446 or toll free (866) 584-5504. There are no user serviceable parts
inside the unit. Periodically, the cables and connectors should be inspected for damage,
corrosion, dust, and dirt. If surfaces are dirty, they can be wiped clean with a cloth moistened
with water and a drop of detergent. Contacts can be wiped clean with a dry cloth.
WARNINGS:
DO NOT OPERATE UNIT IF THERE IS ANY EVIDENCE OF DAMAGE. THE
PRODUCT MUST BE RETURNED TO VECTOR FOR TESTING AND REPAIR.
REPLACE ANY DAMAGED CHARGING ADAPTERS IMMEDIATELY BEFORE
FURTHER USE.
6.
BATTERY DISPOSAL
Contains a maintenance-free, sealed, non-spillable, lead acid battery, which must be disposed
of properly. Recycling is required - contact your local authority for information. Failure to
comply with local, state and federal regulations can result in fines or imprisonment.
W
W
W
WA
A
A
ARRRRN
N
N
NIIIIN
N
N
NG
G
G
GSSSS
• Do not dispose of the battery in fire, as this may result in an explosion
• Before disposing of the battery, protect exposed terminals with
heavy-duty electrical tape to prevent shorting (shorting can result in injury or fire)
• Do not expose battery to fire or intense heat, as it may explode
7.
SPECIFICATIONS
Jump-Start Clamps ............................................................300 Amps - Heavy Duty Copper
Jumper Cables ..............................................................................#6AWGWelding Cable
Peak Amps. ................................................................................................................600
Instant Amps ..............................................................................................................300
Battery High Density AGM ....................................12 Volt, 9 Amp Hour, Sealed, Lead-Acid
Worklight Bulb ......................................................................12 volt, 110 mA festoon type
Accessory Outlet Protection ..................................................12 Amps Self-Resetting Breaker
Height ....................................................................................................9.5 in (24.13 cm)
Width ..........................................................................................................8 in (20.3 cm)
Depth. ..........................................................................................................5 in (12.7 cm)
Weight. ....................................................................................................8.10 lbs (3.6 kg)
CONTAINS SEALED,
NON-SPILLABLE BATTERY
Vec010S manual 03/04  5/22/06  11:19 AM  Page 10