Kenwood TS-590S Manual Do Utilizador

Página de 92
49
6&$1
*52836&$1
110 memory channels are divided into 11 groups 
so that you can select one or more groups to be 
scanned, depending on the situation.
Q 0HPRU\*URXS
When you store frequency data in a memory 
channel, the memory channel belongs to one of 11 
groups as shown below.
MGROUP-0
Memory Channel Nos. 00 ~ 09
MGROUP-1
Memory Channel Nos. 10 ~ 19
MGROUP-2
Memory Channel Nos. 20 ~ 29
MGROUP-3
Memory Channel Nos. 30 ~ 39
MGROUP-4
Memory Channel Nos. 40 ~ 49
MGROUP-5
Memory Channel Nos. 50 ~ 59
MGROUP-6
Memory Channel Nos. 60 ~ 69
MGROUP-7
Memory Channel Nos. 70 ~ 79
MGROUP-8
Memory Channel Nos. 80 ~ 89
MGROUP-9
Memory Channel Nos. 90 ~ 99
MGROUP-P
Memory Channel Nos. P0 ~ P9
Q 6FDQ*URXS6HOHFW
You can select one or more groups to be scanned.  
First, select the groups to be scanned.
Press [M/V] to enter Memory Recall mode.
” appears.
Press and hold [SCAN (SG.SEL)] to enter Scan 
Group Select mode.
As you turn the MULTI/CH control, the
MGROUP number on the sub-display changes.  
MGROUP–0 represents Memory channels 
0 ~ 9, MGROUP–1 represents Memory 
channels 10 ~ 19 and so on up to 
MGROUP–9 which represents Memory 
channels 90 ~ 99 and MGROUP-P which 
represents Memory channels P0 ~ P9. 
Press [M.IN] to select “on” to add the group to 
the Group Scan list.
If you do not want to scan the selected 
Group, press [SCAN (SG.SEL)] to select 
“oFF”.
Press and hold [SCAN (SG.SEL)] or [CLR]. to 
exit the Scan Group Select mode.
Q 3HUIRUPLQJ*URXS6FDQ
Group Scan starts with the smallest group number 
and repeats the sequence.  For example, if you 
selected “on” for MGROUP–3, MGROUP–5, and 
MGROUP–7, the transceiver scans the channels 
in  MGROUP–3 > MGROUP–5 > MGROUP–7 > 
MGROUP–3 and so on.
Select Time-Operated or Carrier-Operated 
mode via Menu No. 22.
Press [M/V] to enter Memory Recall mode.
Turn the SQL control to adjust the squelch 
threshold.
Press [SCAN (SG.SEL] to start Memory Group 
Scan.
Scan ascends up through the channel 
numbers. (The scan direction cannot be 
changed.)
To jump to a desired channel while 
scanning, turn the MULTI/CH control or 
press and hold Mic [UP][DWN].
To stop Scan, press [SCAN (SG.SEL)] or 
[CLR].
Note:
X
If you have turned the SQL control clockwise, far beyond 
the squelch threshold, Scan may fail to stop at a channel 
in which a signal is present.  If this happens, turn the 
SQL control slightly counterclockwise.
X
When the current channel is within one of the groups 
that you selected, Scan starts with the current channel.
X
When the current channel is outside all the groups that 
you selected, Scan starts with the group number that 
is larger than and closest to the group number of the 
current channel.
X
Starting Memory Scan switches OFF the RIT and XIT 
functions.
48,&.0(025<6&$1
Press [Q-MR] to enter Quick Memory mode.
Press [SCAN (SG.SEL] to start Quick Memory 
Scan.
Scan starts from the current quick memory 
channel and ascends up through the channel 
numbers. (The scan direction cannot be 
changed.)
To stop Scan, press [SCAN (SG.SEL)] or [CLR].