13. SENSORS FOR DETECTION AND INSTRUMENT PANEL SIGNALLING
Coolant temperature sensor
Resistor with negative temperature coefficient, providing the 
signal for analog temperature indication.
Operating voltage  
from 6 to 24 V
Calibration range  
from 0° to 120 °C
Resistance value at 90°C 
51.2 ± 4.3 Ω
Electrical poles 
isolated
Low level coolant sensor
Microswitch  sensor  controlled  by  the  float  of  the  coolant 
tank.
Operating voltage:
from 6 to 24 V
Condition for high level
open
Maximum current
2 A not inductive
Electrical poles
isolated
Oil pressure sensor
Rheostat  component  providing  the  signal  for  the  analog 
indication of pressure.
Operating voltage 
from 6 to 24 V
Calibration range  
from 0 to 10 bar
Resistance value at 0 bar 
10 Ω +3/-5 Ω
Resistance value at 2 bar 
52 ± 4 Ω
Resistance value at 4 bar 
88 ± 4 Ω
Resistance value at 6 bar 
124 ± 5 Ω
Maximum value of resistance 
184 Ω
Operating temperature 
from - 25 to 100 °C
Electrical poles 
isolated
Figure 6
Figure 
Figure 8
04_237_n
05_114_C
05_011_V