Kenwood K2E Manual Do Utilizador

Página de 63
TH-K2AT/K2E/K2ET
40
ANT
ANT
ANT
MIC
Encoder
[MENU]
Encoder
[MENU]
[MENU]
LCD
LCD
VR6
VR5
Write
Write
Write
Check
Check
By tuning the
VR6, adjust
the modulation
wave until
if becomes the
square wave.
4.2kHz
According to the
larger +, –.
0.5W ±0.05W
0.8A or less
All segments
are lighted.
■■■■■■■■■
4 to 6 seg-
ments are
lighted.
■■■■ ~
■■■■■■
±0.1kHz
Item
Condition
Measurement
Adjustment
Specifications/
Test equipment
Unit
Terminal
Unit
Parts
Method
Remarks
Low power
3.Battery
terminal
reference
voltage
Adjust/
Check
4.DCS
modulation
balance
5.MAX DEV
8) LCD display: P13C, 
   Frequency: 145.000MHz
   PTT: ON
9) LCD display: P13H, 
   Frequency: 145.995MHz
   PTT: ON
Switch to Adjustment mode
and carry out the operations
for adjustment item B.
(Refer to page 28)
TX power: Low
1)LCD display: BAT
Frequency: 145.000MHz
(E, E3)
Frequency: 146.000MHz
(K, K2, M, M2)
PTT: ON
Battery terminal voltage: 7.5V
To exit from the Adjustment
Mode, turn the transceiver
power OFF and then ON.
2)Frequency: 145.000MHz
(E, E3)
Frequency: 146.000MHz
(K, K2, M, M2)
PTT: ON
Battery terminal voltage: 6.4V
Switch to Adjustment mode
and carry out the operations
for adjustment item L.
(Refer to page 32)
Detector: +P, –P
HPF: OFF    LPF: 3kHz
De-emphasis: OFF
TX power: Low
1)LCD display: DCS.BAL
Frequency: 145.000MHz
(E, E3)
Frequency: 146.000MHz
(K, K2, M, M2)
PTT: ON
To exit from the Adjustment
Mode, turn the transceiver
power OFF and then ON.
MIC terminal input
AG: 1kHz/80mV
Detector: +P, –P
HPF: OFF    LPF: 15kHz
De-emphasis: OFF
TX power: Low
Power meter
Am meter
DC power supply
DVM
Linear detector
Oscilloscope
Linear detector
AG
Oscilloscope
TX-RX
(A/3)
TX-RX
(A/3)
ADJUSTMENT
(Adjust the output voltage from DC power supply until the voltage at the
battery terminal becomes 7.5V while the transceiver is transmitting.)